Air King P1030 Operating Manual Download Page 1

www.airkinglimited.com

00000000 Rev. B 3-08

1 of 20

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always be followed to reduce

the risk of fire, electric shock and injury to person, including the following:

WARNING:

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY

TO PERSONS, PROFESSIONAL SERIES RANGEHOODS MUST BE INSTALLED WITH
PROFESSIONAL SERIES RANGEHOOD BLOWERS THAT ARE MARKED (ON THEIR
CARTONS) TO INDICATE THE SUITABILITY WITH THIS MODEL. OTHER BLOWERS CANNOT
BE SUBSTITUTED.

1.

Read all instructions before installing or using range hood.

2.

Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer.

3.

Before servicing or cleaning the unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.

4.

This unit must be grounded.

5.

To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.

WARNING:

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY

TO PERSON, OBSERVE THE FOLLOWING:

a.) Installation work and electrical wiring must be done by qualified person(s) in

accordance with all applicable codes and standards, including fire-related
construction.

b.) Sufficient air is needed for proper combustion and exhausting of gases through

the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such as
those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

c.) When cutting or drilling into wall or ceiling, do not damage electrical wiring

and other hidden utilities.

d.) Ducted fans must always be vented to the outdoors.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST

HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

CAUTION:

 

TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR,

BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST AIR INTO SPACES WITHIN
WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES, OR GARAGES.

Professional Series

Range Hood

SAVE THESE INSTRUCTIONS

CAUTION:

 

TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, INSTALL

THIS RANGEHOOD ONLY WITH INTEGRAL BLOWERS MANUFACTURED BY AIR KING,
MODEL(S) B1125, B900, B600, B500, OR B300 ONLY.

WARNING:

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE

THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings. Boilovers cause smoking

and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambéing food (ie.

Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c) Clean ventilating fans frequently. Grease should not be allowed to accumulate

on fan filter.

d) Use proper pan size. Always use cookware appropriate for the size of the

surface element.

WARNING:

 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT

OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn

off burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - You may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam

explosion will result.

d) Use an extinguisher ONLY if:

I.

You know you have a Class ABC extinguisher, and you already know how

to operate it.

II.

The fire is small and contained in the area where it started.

III. The fire department is being called.

IV. You can fight the fire with your back to an exit.

WARNING:

 

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

Summary of Contents for P1030

Page 1: ...can Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always be vented to the outdoors CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS CAUTION TO REDUCE THE RISK ...

Page 2: ... with a protective plastic adhered to the range hood It is recommended to leave this in place during installation to protect the hood from scratching Remove when the installation is complete 2 Remove the wood mounting strip attached to the back of the hood and place in a secure place You will need this strip later Figure 1 3 Remove the two screws securing the grease trough in place These have been...

Page 3: ...up the four holes on the flange of the adapter to the four corresponding holes on the hood and secure in place with the provided screws Ensure an airtight seal around the adapter by securing all connections with ducting tape Figure 8 3 of 20 Figure 7 Horizontal Vertical Roof Cap Wall Cap Outlet Adapter Outlet Adapter Flange Screws Hood Figure 8 Figure 6 Hood Wall Anchor 3 It is highly recommended ...

Page 4: ... Make sure the strips line up to the holes in the top of the canopy 4 Mark the location where the outlet adapter available separately will be located on the cabinets and cut a hole approximately 1 larger on all sides than the outlet adapter Figure 13 NOTE If the recommended optional BS Series backsplash is being installed use the template to locate and drill the appropriate holes for mounting The ...

Page 5: ...CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the two wire compartment cover screws to gain access into the wire compartment Figure 19 Connect the white wire from the range hood to the white wire from the supply and the black wire from the range hood to the black wire of the su...

Page 6: ...robable Cause Suggested Remedy 1 Hood does not operate when the switch is on 1a A fuse may be blown or a circuit tripped 1a Replace fuse or reset circuit breaker 1b Wiring is not connected properly 1b Turn off power to unit Check that all wires are connected 2 Hood is operating but air moves slower than normal 2 Obstruction in the exhaust ducting 2 Check for any obstructions in the ducting includi...

Page 7: ...www airkinglimited com 00000000 Rev B 3 08 7 of 20 ...

Page 8: ... autorités locales du code c Lors de coupe ou de perçage des murs et plafonds ne pas endommager le filage électrique et autres utilités cachées d Ducted Fans must always be vented to the outdoors AVERTISSEMENT POUR USAGE DE VENTILATION GÉNÉRALE EXCLUSIVEMENT NE PAS UTILISER POUR ÉVACUER DU MATÉRIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES AVERTISSEMENT POUR RÉDUIRE LES RISQUES D INCENDIE ET POUR É...

Page 9: ... de l installation de la hotte REMARQUE Avant d installer des pièces ou de marquer des emplacements assurez vous d avoir décidé comment seront installés les conduits Vous pourriez avoir besoin de modifier la structure tel que décrit à la Section 5 Installation au mur de couvert de la hotte ou la Section 6 Installation sous l armoire de couvert de la hotte 1 Les mesures pour l installation seront p...

Page 10: ...tateur mural de la bonne taille requise disponible séparément à la hotte en appariant les quatre trous sur la bride de l adaptateur aux quatre trous correspondants sur la hotte et fixer en place avec les vis comprises Assurez vous que le joint est étanche autour de l adaptateur en sécurisant tous les raccords avec du ruban de gaine Figure 8 Figure 6 Hotte Ancrages muraux Figure 7 Horizontal Vertic...

Page 11: ...e sortie horizontale devra être utilisé si vous évacuez l air par le biais d une trappe murale Languette en bois Figure 12 Trou Figure 13 Figure 14 REMARQUE Lorsque la terminaison du conduit est similaire à celle illustrée à la figure 15 passant au travers du mur sur lequel la hotte est installée l installation requiert une considération spéciale Dépendant de où les montants muraux sont situés il ...

Page 12: ...e de la hotte Figure 21 3 Installer les filtres déflecteurs avec les barres d espacement qui sont requises en insérant le dessus du filtre dans le canal du haut de la hotte puis glisser le bas du filtre dans le canal du bas Les filtres ont un sens pour le haut et le bas Le bas sur le filtre aura des petits trous pour le drainage Ces trous doivent faire face vers le bas en direction du dalot à grai...

Page 13: ...œuvre ou le coût de remplacement de composantes faisant partie d entretien de routine tels que Filtres à graisse des hottes de cuisine filtres au charbon ou combiné filtre à graisse charbon ampoules électriques de remplacement dans les hottes de cuisine ou les combinés ventilateur lumière chaufferette pour salle de bain Aussi tout dommage ou défaillance causé par un abus une mauvaise utilisation u...

Page 14: ...www airkinglimited com 14 of 20 00000000 Rev B 3 08 ...

Page 15: ...SPACIOS ENTRE PAREDES O CIELORRASOS O DENTRO DE ÁTICOS ESPACIOS BAJO EL PISO O GARAJES CONSERVE ESTAS INSTRUCCIONES PRECAUCIÓN PARA REDUCIR EL RIESGO DE INCENDIO Y CHOQUE ELÉCTRICO INSTALE ESTA CAMPANA EXTRACTORA ÚNICAMENTE CON SOPLADORES INTEGRALES FABRICADOS POR AIR KING MODELO S B1125 B900 B600 B500 Ó B300 ÚNICAMENTE ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELÉCTRICO NO USE ESTE EX...

Page 16: ... para la instalación de la campana NOTA Antes de instalar cualquier parte o marcar ubicaciones asegúrese de haber decidido cómo va a instalar sus tuberías Es probable que usted necesite modificar la estructura de la pared según lo descrito en la Sección 5 de instalación de bóveda montada en pared o en la Sección 6 de instalación de bóveda bajo gabinete 1 Las mediciones para la instalación deben ad...

Page 17: ...n los cuatro orificios correspondientes en la campana y asegure en su lugar con los tornillos suministrados Garantice un sellado hermético alrededor del adaptador asegurando todas las conexiones con cinta de embalar Figura 8 Figura 6 Campana Ancla de pared 3 Es altamente recomendable la instalación de un regulador de corriente invertida de aire para evitar que el aire exterior vuelva a ingresar a ...

Page 18: ...s Asegúrese que los listones estén alineados con los agujeros en la parte superior de la bóveda 4 Marque la ubicación donde se ubicará el adaptador de salida disponible por separado en los gabinetes y corte un agujero de aproximadamente 25 4 mm más grande en todos los costados que el adaptador de salida Figura 13 NOTA Si se va a instalar el protector contra salpicaduras opcional de la serie BS use...

Page 19: ...NES ELÉCTRICAS DEBEN HACERSE EN CUMPLIMIENTO DE LOS CÓDIGOS Y LAS ORDENANZAS LOCALES O CON EL CÓDIGO ELÉCTRICO NACIONAL SI USTED NO ESTÁ FAMILIARIZADO CON LOS MÉTODOS DE INSTALACIÓN DEL CABLEADO ELÉCTRICO ASEGÚRESE DE CONTAR CON LOS SERVICIOS DE UN ELECTRICISTA CALIFICADO 1 Retire los dos tornillos de la cubierta del compartimiento de cables para tener acceso al compartimiento de cables Figura 19 ...

Page 20: ...a luz 5S1136071 8 1 Placa del Interruptor 5S1136072 9 2 Perillas 5S1136073 10 1 Canaleta para grasa 762 mm 5S1136074 Canaleta para grasa 914 4 mm 5S1136089 Canaleta para grasa 1066 8 mm 5S1136090 Canaleta para grasa 1219 2 mm 5S1136091 11 Portalámparas de la lámpara halógena 5S1136075 12 1 Portalámparas de la lámpara de calor 5S1136076 13 Filtro deflector PHGB1 5S1136077 Filtro deflector PHGB2 5S1...

Reviews: