This section explains the settings of each function, including the master code for management, the user code for unlocking, the 

buzzer and the LEDs. 

About the setting mode:

Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for 

the desired function. After settings have been made, enter the following setting codes to continue the setting operation. 

Press   to exit the setting mode.

Setting items

Allowable setting range 

Default value Setting code

  Setting the code length

Change the length of the master code and the user code. 

)They both must be the same length.

4, 5, or 6 digits

4 digits

  Setting the master code

Enter a master code using between 4 and 6 digits (alpha or numeric) to 

switch to the setting mode. 

) The number of digits in the code can be set by setting the code length.

1

Valid keys: 0 - 9, A, B

1234

  Setting the code for user group 1

Set the unlocking code for user group 1. 

) The number of digits in the code can be set by setting the code length.

Number of codes: 60

Valid keys: 0 - 9, A, B

-

 - 

  Setting the code for user group 2

Set the unlocking code for user group 2. 

) The number of digits in the code can be set by setting the code length.

Number of codes: 40

Valid keys: 0 - 9, A, B

-

 - 

  Setting the key illumination time

Set the length of time that the keys will be lit up after they are pressed. 

Illumination time: 10 to 99 

seconds, or continually lit

10 Sec.

  Setting the relay 1 output time

Set the output time of relay 1.

Output time: 1 to 99 

seconds, or latched

3 Sec.

  Setting the relay 2 output time

Set the output time of relay 2.

Output time: 1 to 99 

seconds, or latched

3 Sec.

  Reset Settings

Return all the settings to their default values.

-

-

  External output setting

The alarm or security system connected to the terminal of relay 2 will be 

activated when the "Lockout" * or the forced entry* is carried out.   

* "Lockout": Refer to VIII below. *Forced entry: This function is linked with 

the door open/close sensor (N.C.) which is connected to PB2 and C, and 

carried out when opening the door without activating this unit. (For example, 

entry in an improper manner, manual unlock, etc.)

) If there is a way to open the door without activating this unit, such as 

manual unlock, do not make the external output setting for the forced entry.  

· OFF

·  During Lockout 

·  During forced entry output

·  

During lockout and forced 

entry output

OFF

  Lockout

If several incorrect access codes are attempted, the code input function is 

disabled for a programmed period of time.

·   When "Lockout" is activated, the LED (Orange) indicator and the keypad 

blink, and the buzzer sounds for 3 seconds. This is just a sound to inform 

you that the function has been activated. It is not a warning sound. If you 

want a warning to be sounded, please use the external output function to 

activate a commercially-available alarm device.

·  The unlock function will work when the request to exit/entry button is 

pushed, even while the "Lockout" function is operating.

ON/OFF

Invalid number of times: 

 

10 to 99 times

Invalid time: 

 

10 to 99 seconds

OFF

  Auto-relock (Anti-tailgate)

After the door has been linked to the door open/close sensor (N/C), and 

unlocked, it will relock itself one second after being closed, thus preventing 

the entry of an unauthorized third party.  1

ON/OFF

OFF

  Timer-linked unlocking setting

The system can be set to unlock the door by pressing the 

 key within 

the set time and linking it to the external timer (N/O). The operations for the 

LEDs and the buzzer after unlocking are the same as those used to perform 

user code unlocking. When the door is linked to the timer, unlocking can be 

performed using the user code and the request to exit/entry button. When 

latch output is performed for the relay settings, the relay turns ON/OFF 
every time the 

 key is pressed.

Linked relay: relay 1

relay 2

relay 1 and 2

0 key illumination: ON/OFF

Linked relay: relay 1

0 key illumination: OFF

  Operation tone settings

Set the tone heard when the keypad is being used to ON/OFF.

ON/OFF

ON

•  The setting can be saved even when the power is off. 

•  The system cannot be switched to the setting mode while the relay is unlocked.

•  When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system 

will exit the setting mode. (If a key is pressed during that time, the timer will start over.)

•  Neither the request to exit/entry button nor the timer-linked unlocking

 

 key can be operated, and unlocking using the 

user code cannot be performed while the setting mode is activated.

•  The volume (the check tone, operation tone, etc.) from the door station may become lower according to the mounting status.

: When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is 

only possible when user code unlocking is performed.

FUNCTIONS/SETTING UP FOR ACCESS CONTROL

JK-DVF-AC_ENG.indd   7

2009/10/05   21:18:42

Summary of Contents for JK-DVF-AC

Page 1: ...eur r sistante au vandalisme avec clavier codes r tro clair Antivandalisme deurpost met kleurencamera en ingebouwd codeklavier 83799600 A P1009YZ INSTALLATION OPERATION MANUAL MANUEL D INSTALLATION ET...

Page 2: ...CLAVIER Faire en sorte de bien noter vos r glages ci dessous LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES VOOR CODEKLAVIER Zorg ervoor uw instellingen hieronder op te schrijven External output set...

Page 3: ...where the temperature is quite low such as inside a refrigerated area or in front of air conditioner Places subject to steam or smoke near heating or cooking surfaces Where noise generating devices s...

Page 4: ...wn Mounting position 1 500 mm 5 Left Right Approx 1 050 mm 3 5 Approx 2 050 mm 6 9 Approx 1 000 mm 3 4 500mm 20 1 500 mm 5 Unit center Approx 1 850 mm 6 2 Approx 1 050 mm 3 5 Approx 800 mm 2 7 Mountin...

Page 5: ...ut by wrapping insulation tape around the end of the jacket Additionally position the cable downward to prevent rainwater or moisture from seeping into the cable l Do not bend the wires at a sharp ang...

Page 6: ...supply Between 12 and 24V AC Between 12 and 24V DC Request to exit entry button Timer Minimum overload 100mV DC 0 1mA or above Contact capacity 3V DC 0 1A or above Relay 24V DC 3A resistive load 1A i...

Page 7: ...ry button To set the auto relock External output by forced entry function a sensor locally available is required The request to exit entry button for relay 2 cannot be used when the auto relock Extern...

Page 8: ...During lockout and forced entry output OFF Lockout If several incorrect access codes are attempted the code input function is disabled for a programmed period of time When Lockout is activated the LED...

Page 9: ...twice Blinking Illumination Illumination When a user code that has already been set is selected When a user code that has already been set is selected Blinking Illumination Blinking group 1 Bleep Blee...

Page 10: ...times 00 Illumination Blinking Illumination Blinking Beep Bleep When the key is pressed the green LED lights up the buzzer beeps twice and the system exits the setting mode If the key is included in...

Page 11: ...is on 0 key illumination OFF while timer is on 0 key illumination ON while timer is on 0 key illumination OFF while timer is on Inputting the number of operations ex 10 times 10 99 Inputtinglengthoft...

Page 12: ...inked unlocking When the timer linked unlocking function is active the door can be unlocked by pressing the key during the set time while the timer is linked The key illumination lights up when the ti...

Page 13: ...on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses tha...

Reviews: