 Connection of Relay 1 only

Electric door strike

AC transformer

Power supply

2 NP

2 NP

2 NP

2 NP

2 NP

2

NP

2

NP

Automatic gate

Power supply

Request to exit/entry button
(push button, etc.)

Electromagnetic

door lock

V

V

PB1 PB2

C

T

NO1 C1

NC1 NO2

C2 NC2

NO1 C1

NC1 N

NO1 C1

PS

NC1 NO2 C

A1

A2

JK-1MD

JK-1MED

JK-1MED/1MD

A1 A2

L

L

JK-DVF-AC

n

 Relay 1: Automatic gate (N/O contact), Relay 2: Electric door strike (N/O contact)

Power supply
Rating
Between 12 and 24V AC
Between 12 and 24V DC

Automatic gate

Timer

For relay 2 
Request to 
exit/entry button

For relay 1 
Request to 
exit/entry button

To set the

 

"auto-relock" / "External output by forced entry" function, 

a sensor (locally available) is required.

The request to exit/entry button for relay 2 cannot be used when the 

"auto-relock" / "External output by forced entry" functions are set.

Electric door strike

AC transformer

Auto-relock/External output by forced entry   
(sensor connection is required)

2

NP

2

NP

A1

A2

JK-1MD

JK-1MED

A1 A2

L

L

V

V

PB1 PB2

C

T

NO1 C1

NC1 NO2

C2 NC2

Alarm, Security

Only connecting to the terminal 
of relay 2 is possible.

External output

NO2 C2

2 NP

2

NP

2

NP

2

NP

2 NP

2 NP

PB2

N.C

C

JK-DVF-AC

JK-1MED/1MD

or

or

or

or

Example of electric door 

strike connection (N/O)

Example of automatic 

gate connection (N/O)

Example of electromagnetic 

door lock connection (N/C)

Connection examples

JK-DVF-AC_ENG.indd   6

2009/10/05   21:18:39

Summary of Contents for JK-DVF-AC

Page 1: ...eur r sistante au vandalisme avec clavier codes r tro clair Antivandalisme deurpost met kleurencamera en ingebouwd codeklavier 83799600 A P1009YZ INSTALLATION OPERATION MANUAL MANUEL D INSTALLATION ET...

Page 2: ...CLAVIER Faire en sorte de bien noter vos r glages ci dessous LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES VOOR CODEKLAVIER Zorg ervoor uw instellingen hieronder op te schrijven External output set...

Page 3: ...where the temperature is quite low such as inside a refrigerated area or in front of air conditioner Places subject to steam or smoke near heating or cooking surfaces Where noise generating devices s...

Page 4: ...wn Mounting position 1 500 mm 5 Left Right Approx 1 050 mm 3 5 Approx 2 050 mm 6 9 Approx 1 000 mm 3 4 500mm 20 1 500 mm 5 Unit center Approx 1 850 mm 6 2 Approx 1 050 mm 3 5 Approx 800 mm 2 7 Mountin...

Page 5: ...ut by wrapping insulation tape around the end of the jacket Additionally position the cable downward to prevent rainwater or moisture from seeping into the cable l Do not bend the wires at a sharp ang...

Page 6: ...supply Between 12 and 24V AC Between 12 and 24V DC Request to exit entry button Timer Minimum overload 100mV DC 0 1mA or above Contact capacity 3V DC 0 1A or above Relay 24V DC 3A resistive load 1A i...

Page 7: ...ry button To set the auto relock External output by forced entry function a sensor locally available is required The request to exit entry button for relay 2 cannot be used when the auto relock Extern...

Page 8: ...During lockout and forced entry output OFF Lockout If several incorrect access codes are attempted the code input function is disabled for a programmed period of time When Lockout is activated the LED...

Page 9: ...twice Blinking Illumination Illumination When a user code that has already been set is selected When a user code that has already been set is selected Blinking Illumination Blinking group 1 Bleep Blee...

Page 10: ...times 00 Illumination Blinking Illumination Blinking Beep Bleep When the key is pressed the green LED lights up the buzzer beeps twice and the system exits the setting mode If the key is included in...

Page 11: ...is on 0 key illumination OFF while timer is on 0 key illumination ON while timer is on 0 key illumination OFF while timer is on Inputting the number of operations ex 10 times 10 99 Inputtinglengthoft...

Page 12: ...inked unlocking When the timer linked unlocking function is active the door can be unlocked by pressing the key during the set time while the timer is linked The key illumination lights up when the ti...

Page 13: ...on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses tha...

Reviews: