English

WARNING

(Negligence could result in death or serious injury to 

people)

1.  The unit must be installed and wired by a qualified 

technician. Having installation performed by an 

unqualified technician could result in electric shock.

2.  Do not connect any non-specified power source to the 

V, V terminals, and do not install two power supplies in 

parallel to a single input. Fire, damage to the unit, or 

system malfunction could result.

3.  The unit is not explosion-proof. Do not install or use 

near gases or flammable materials. Fire or explosion 

could result.

4.  Do not dismantle or alter the unit. Fire or electric shock 

could result.

5.  Do not allow the wires or DC output terminals to be 

shorted. Fire or electric shock could result.

6.  Existing wiring such as chime wiring, etc. may contain 

high voltage AC electricity. Damage to the unit or 

electric shock could result. Wiring and installation 

should be done by a qualified technician.

CAUTION

(Negligence could result in injury to people or damage 

to property)

1.  When mounting the unit on a wall, install the unit in a 

convenient location, but not where it could be jarred or 

bumped. Injury could result.

2.  Do not install or make any wire terminations while 

power supply is plugged in. It can cause electrical 

shock or damage to the unit.

3.  Before turning on power, make sure wires are not 

crossed or shorted. Fire or electric shock could result.

4.  Do not install the unit in any of the following locations. 

Fire, electric shock, or unit trouble could result.

*  Places 

sub

ject to dust, oil, chemicals, hydrogen 

sulfide (hot spring).

*  Places subject to moisture and humidity extremes, 

such as bathroom, cellar, greenhouse, etc.

*  Places where the temperature is quite low, such 

as inside a refrigerated area or in front of air-

conditioner.

*  Places subject to steam or smoke (near heating or 

cooking surfaces).

*  Where noise generating devices such as dimmer 

switches, invertor electrical appliances, are closeby.

5.  Do not put anything on the unit or cover the unit with 

cloth, etc. Fire or unit trouble could result.

GENERAL PRECAUTIONS

1.  This product, being a control unit of door release, 

should not be used as a crime-prevention device.

2.  This product is weather-resistant, but do not spray 

high-pressure water on it. Unit trouble could result.

3.  The product becomes inoperative during power failure.
4.  As to other manufacturer's devices, such as sensor, 

door releases, timer, used with this system, comply 

with the Specifications and Warranty conditions 

manufacturers or venders present.

5.  When outside temperature lowers sharply after rainfall, 

etc., the inside of the camera may fog up slightly, 

causing a blurry picture, but this is not a malfunction. 

Normal operation will be restored when moisture 

evaporates.

6.  Due to the environmental sound around the unit, it 

may hinder smooth communication, but this is not a 

malfunction.

RECORD OF SETTINGS AND REGISTRATION
DETAILS FOR ACCESS CONTROL ……………………… 1
PRECAUTIONS  …………………………………………… 2
PACKAGE CONTENTS  …………………………………… 3
MOUNTING  ………………………………………………… 3
PART NAMES  ……………………………………………… 4

WIRING AND CONNECTIONS

  …………………………… 5

FUNCTIONS/SETTING UP FOR ACCESS CONTROL … 7
OPERATION OF ACCESS CONTROL ………………… 11
TECHNICAL PRECAUTIONS  ………………………… 11
SPECIFICATIONS  ……………………………………… 12

WARRANTY

 ……………………………………………… 12

General Prohibitions     Prohibition to Dismantle the Unit     General Precautions  

PRECAUTIONS

CONTENTS

Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully 
before installation, and keep it in a safe place for future reference.

*  Refer to the “INSTALLATION & OPERATION MANUAL” for the JK-1MED or JK-1MD for complete 

information regarding this system. 

JK-DVF-AC_ENG.indd   2

2009/10/05   21:18:31

Summary of Contents for JK-DVF-AC

Page 1: ...eur r sistante au vandalisme avec clavier codes r tro clair Antivandalisme deurpost met kleurencamera en ingebouwd codeklavier 83799600 A P1009YZ INSTALLATION OPERATION MANUAL MANUEL D INSTALLATION ET...

Page 2: ...CLAVIER Faire en sorte de bien noter vos r glages ci dessous LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES VOOR CODEKLAVIER Zorg ervoor uw instellingen hieronder op te schrijven External output set...

Page 3: ...where the temperature is quite low such as inside a refrigerated area or in front of air conditioner Places subject to steam or smoke near heating or cooking surfaces Where noise generating devices s...

Page 4: ...wn Mounting position 1 500 mm 5 Left Right Approx 1 050 mm 3 5 Approx 2 050 mm 6 9 Approx 1 000 mm 3 4 500mm 20 1 500 mm 5 Unit center Approx 1 850 mm 6 2 Approx 1 050 mm 3 5 Approx 800 mm 2 7 Mountin...

Page 5: ...ut by wrapping insulation tape around the end of the jacket Additionally position the cable downward to prevent rainwater or moisture from seeping into the cable l Do not bend the wires at a sharp ang...

Page 6: ...supply Between 12 and 24V AC Between 12 and 24V DC Request to exit entry button Timer Minimum overload 100mV DC 0 1mA or above Contact capacity 3V DC 0 1A or above Relay 24V DC 3A resistive load 1A i...

Page 7: ...ry button To set the auto relock External output by forced entry function a sensor locally available is required The request to exit entry button for relay 2 cannot be used when the auto relock Extern...

Page 8: ...During lockout and forced entry output OFF Lockout If several incorrect access codes are attempted the code input function is disabled for a programmed period of time When Lockout is activated the LED...

Page 9: ...twice Blinking Illumination Illumination When a user code that has already been set is selected When a user code that has already been set is selected Blinking Illumination Blinking group 1 Bleep Blee...

Page 10: ...times 00 Illumination Blinking Illumination Blinking Beep Bleep When the key is pressed the green LED lights up the buzzer beeps twice and the system exits the setting mode If the key is included in...

Page 11: ...is on 0 key illumination OFF while timer is on 0 key illumination ON while timer is on 0 key illumination OFF while timer is on Inputting the number of operations ex 10 times 10 99 Inputtinglengthoft...

Page 12: ...inked unlocking When the timer linked unlocking function is active the door can be unlocked by pressing the key during the set time while the timer is linked The key illumination lights up when the ti...

Page 13: ...on site service calls Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses tha...