background image

 

 

Buttons

 

for

 

Menu

 

Navigation

 

ENG

 

-

 

Functions

 

as

 

an

 

UP

 

button

 

in

 

this

 

menu.

 

Pressing

 

ENG

 

sequentially

 

advances

 

the menu

 

to

 

the

 

next

 

item.

 

MDE

 

-

 

Functions

 

as

 

a

 

DOWN

 

button

 

in

 

this

 

menu.

 

Pressing

 

MDE

 

sequentially

 

advances the

 

menu

 

to

 

the

 

previous

 

item.

 

CLR

 

-

 

Pressing

 

CLR

 

will

 

exit

 

from

 

the

 

PROGRAM

 

MENU

 

and

 

return

 

the

 

unit

 

to

 

ACTIVE DISPLAY

 

MODE.

 

ENT

 

-

 

Pressing

 

ENT

 

will

 

change

 

the

 

current

 

item

 

as

 

advanced

 

to

 

or

 

displayed

 

in

 

the PROGRAM

 

MENU

 

 

AC

 

Auto

 

Clear

 

is

 

time,

 

in

 

seconds

 

1-9

 

and

 

off. When

 

AC

 

is

 

displayed,

 

pressing

 

ENT

 

will sequentially

 

advance

 

the

 

time

 

increment

 

by

 

1

 

second

 

at

 

each

 

press

 

of

 

ENT.

 

After

 

5 seconds

 

of

 

no

 

changes,

 

the

 

unit

 

will

 

revert

 

to

 

Active

 

Display

 

Mode

 

and

 

the

 

last

 

shown setting

 

will

 

be

 

held.

 

Setting

 

OFF

 

will

 

deactivate

 

the

 

Auto

 

Clear

 

function

 

and

 

readings

 

will need

 

to

 

be

 

cleared

 

from

 

the

 

screen

 

manually

 

using

 

the

 

CLR

 

key.

 

 

FILT

 

Peak

 

filter

 

frequency

 

response

 

in

 

Hz.

 

Options

 

of

 

125,

 

250,

 

500,

 

750

 

and

 

1500

 

are

 

available.

 

Press

 

ENT

 

key

 

to

 

sequentially

 

scroll

 

thru

 

these

 

options.

 

After

 

5

 

seconds

 

of

 

no changes,

 

the

 

unit

 

will

 

revert

 

to

 

Active

 

Display

 

Mode

 

and

 

the

 

last

 

shown

 

setting

 

will

 

be held.

 

 

PPER

 

(PEAK

 

BLANKING)

 

Minimum

 

peak

 

as

 

a

 

percentage

 

of

 

full

 

scale.

 

Readings

 

below

 

the

 

SET

 

value

 

will

 

not

 

be displayed.

 

Settings

 

in

 

the

 

range

 

of

 

2%-50%

 

are

 

available.

 

Pressing

 

ENT

 

will

 

sequentially increase

 

the

 

%

 

by

 

one

 

with

 

each

 

press.

 

At

 

50%

 

the

 

unit

 

will

 

scroll

 

back

 

to

 

2%

 

with

 

the next

 

press

 

of

 

ENT.

 

After

 

5

 

seconds

 

of

 

no

 

changes,

 

the

 

unit

 

will

 

revert

 

to

 

Active

 

Display Mode

 

and

 

the

 

last

 

shown

 

setting

 

will

 

be

 

held.

 

 

SL

 

Sign

 

Lock.

 

Options

 

of

 

ON

 

or

 

OFF

 

are

 

available.

 

Press

 

ENT

 

to

 

scroll

 

between

 

the

 

selections. After

 

5

 

seconds

 

of

 

no

 

changes,

 

the

 

unit

 

will

 

revert

 

to

 

Sample

 

Mode

 

and

 

the

 

last

 

shown setting

 

will

 

be

 

held.

 

 

LOW

 

Lower

 

limit

 

target.

 

A

 

setting

 

of

 

0.000

 

disables

 

the

 

limit.

 

Press

 

ENT

 

to

 

enter

 

the

 

Number Edit

 

Mode.

 

 

The

 

current

 

digit

 

or

 

decimal

 

point

 

flashes.The

 

Number

 

Edit

 

Mode

 

will

 

remain

 

active

 

without

 

time

 

out

 

until

 

the

 

CLR

 

button

 

is

 

pressed. 

 
Press

 

ENG

 

to

 

sequentially

 

increase

 

the

 

flashing

 

digit.

 

Press

 

MDE

 

to

 

sequentially

 

decrease the

 

flashing

 

digit.

 

Press

 

ENT

 

to

 

save

 

the

 

digit

 

and

 

move

 

on

 

to

 

the

 

next.

 

 

Once

 

all

 

digits

 

have

 

been

 

adjusted/ 

entered

 

the

 

decimal

 

point

 

is

 

able

 

to

 

be

 

moved.

 

ENG will

 

then

 

move

 

the

 

decimal

 

one

 

position

 

to

 

the

 

right

 

with

 

each

 

press.

 

MDE

 

will

 

move

 

the decimal

 

point

 

one

 

position

 

to

 

the

 

left

 

with

 

each

 

press.

 

Press

 

PROGRAM MENU

 

Summary of Contents for Auditor TORQUE CUBE

Page 1: ...TORQUE CUBE OPERATIONS MANUAL ...

Page 2: ... Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electrical shock PERSONAL SAFETY Stay alert observe the task at hand and use common sense when using product Do not use when tired or under the influence of drugs alcohol or medication A moment of inattention can cause personal injury Use safety equipment Always wear eye protection Safety equip...

Page 3: ...s to securely mount your Auditor Torque Cube to the workstation prior to use The Auditor Torque Cube is setup with thru holes for 3 8 9 mm x 4 100 mm fastening bolts or screws During operational use the AuditorTorque Cube is subjected to rotational forces that require 2 points of attachment to the work station to secure against Dowel pins of at least 2 50 mm may also be used at the work station wh...

Page 4: ...or use with a serial printer or Windows PC device Dimensions 3 125 79 375 mm Wide 3 75 95 25 mm High 3 23 82 55 mm Deep 2 5 lb 1 13 kg Power Requirements 9 26V DC 150 mA min Supplied by 100 220VAC Input Transformer Battery Internal non field serviceable NiMh pack 32 F 0 C to 122 F 50 C Data Communications RS 232 Accuracy 1 of Indicated Reading within top 90 of Full Scale Range 10 to 100 of Full Sca...

Page 5: ...the same direction a simulated hard joint is achieved Fig B Alignment of the concave shapes in an opposing manner a simulated soft joint is achieved Fig C Differing combinations allow for simulated medium joints to be achieved Fig D Fig A Fig B Fig C Fig D Prior to use remove the Joint Simulator from its bag Loosen the Hex Screw and stack the Bellville Washers according to your joint condition nee...

Page 6: ...gh the available units Kgf M Kgf Cm gf Cm Ncm Nm FT LB IN LB IN OZ Pressing any other key will return to SAMPLE mode ENT Pressing ENT will send the current reading to the serial port and clears the screen MDE ENG Pressing MDE ENG buttons simultaneously displays the Program Menu See Program Menu section for details ACTIVE DISPLAY Active Display Mode is the normal operating mode used by the Auditor ...

Page 7: ...st shown setting will be held PPER PEAK BLANKING Minimum peak as a percentage of full scale Readings below the SET value will not be displayed Settings in the range of 2 50 are available Pressing ENT will sequentially increase the by one with each press At 50 the unit will scroll back to 2 with the next press of ENT After 5 seconds of no changes the unit will revert to Active Display Mode and the ...

Page 8: ...ers 1 20 Pressing ENT at the number 20 scrolls the menu selection back to OFF After 5 seconds of no changes the unit will revert to Active Display Mode and the last shown setting will be held The internal battery pack contained in the Auditor Torque Cube is non user serviceable When treated properly the battery pack should provide approximately 12 hours of continuous use from a full charge The bat...

Page 9: ... RS232 cable enabling connection to a seRial printer data collector computer or other RS 232 enabled device Values are sent via RS 232 each time the unit Auto Clears AC or the ENT or CLR buttons are pressed RS 232 Transfer Protocol Protocol Value Cable P N RS232C Mini Plug Auditor CUBE Dsub 9 Pin Baud Rate 9600 Parity None Bits 8 Stop Bit 1 Flow None RS 232 Data Stream Format Mmmbsdddddbuuuuucl wh...

Page 10: ...set level HIGH LIMIT Use the High Limit setting as a means of visually alerting the operator when a reading is above a desired maximum value The RED LED will illuminate to let the operator know that the achieved reading was above the preset level CAL For factory authorized service center use only NEW TOOL AND ACCESSORY WARRANTY Any new tool or accessory branded withtheAIMCO Uryu AcraDyne or Eagle ...

Page 11: ...es the right to make these changes without incurring any obligation or incorporating such changes or updates in tools or parts previously distributed THE AIMCO WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND AIMCO EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS WARRANTY SETS FORTH THE SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT STRIC...