background image

 

 

When

 

viewing

 

the

 

Auditor

 

Torque

 

Cube™

 

from

 

the

 

operators

 

perspective,

 

there

 

are

 

2 connectors

 

on

 

the

 

left

 

side

 

of

 

the

 

unit.

 

 

DC

 

IN

 

The

 

interface

 

for

 

the

 

AC

 

Adapter

 

that

 

was

 

supplied

 

with

 

the

 

unit

 

is

 

the

 

upper

 

connector. This

 

connection

 

may

 

be

 

used

 

when

 

the

 

unit

 

is

 

charging

 

or

 

during

 

operation.

 

Use

 

only

 

the supplied

 

Auditor

 

Torque

 

Cube™

 

AC

 

Adapter

 

with

 

this

 

unit.

 

Use

 

of

 

any

 

other

 

adapter

 

may 

cause

 

damage

 

to

 

the

 

unit.

 

 

RS-232

 

The

 

lower

 

connector

 

is

 

for

 

an

 

RS-232

 

(P/N

 

RS232)

 

cable

 

enabling

 

connection

 

to

 

a

 

seRial

 

printer,

 

data

 

collector,

 

computer

 

or

 

other

 

RS-232

 

enabled

 

device.Values

 

are

 

sent

 

via RS-

232

 

each

 

time

 

the

 

unit

 

Auto

 

Clears

 

(AC)

 

or

 

the

 

ENT

 

or

 

CLR

 

buttons

 

are

 

pressed.

 

 
 

 

 

RS-232

 

Transfer

 

Protocol

 

Protocol

 

Value

 

Cable

 

P/N

 

RS232C

 

Mini-Plug

 

(Auditor

 

CUBE)

 

 

Dsub

 

9

 

Pin

 

Baud

 

Rate

 

9600

 

Parity

 

None

 

Bits

 

8

 

Stop

 

Bit

 

1

 

Flow

 

None

 

 
 

RS-232

 

Data

 

Stream

 

Format

 

Mmmbsdddddbuuuuucl

 

where:

 

 

m

 

=

 

Memory

 

Location

 

b

 

=

 

Blank

 

s

 

=

 

Sign

 

(Space

 

or

 

-)

 

d

 

=

 

Data

 

with

 

Decimal

 

Point

 

u

 

=

 

Units

 

c

 

=

 

Carriage

 

Return

 

l

 

=

 

Line

 

Feed

 

 

RS-232

 

Cable

 

Pinouts

 

Pin#

 

Description

 

1

 

Unused

 

2

 

Transmit

 

3

 

Receive

 

4

 

Unused

 

5

 

Ground

 

6

 

Unused

 

7

 

Unused

 

8

 

Unused

 

9

 

Unused 

 
 
 
 
 
 
 
 
 
 
 

 

SIDE PANEL INPUT / OUTPUT

 

RS-232

 

Summary of Contents for Auditor TORQUE CUBE

Page 1: ...TORQUE CUBE OPERATIONS MANUAL ...

Page 2: ... Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electrical shock PERSONAL SAFETY Stay alert observe the task at hand and use common sense when using product Do not use when tired or under the influence of drugs alcohol or medication A moment of inattention can cause personal injury Use safety equipment Always wear eye protection Safety equip...

Page 3: ...s to securely mount your Auditor Torque Cube to the workstation prior to use The Auditor Torque Cube is setup with thru holes for 3 8 9 mm x 4 100 mm fastening bolts or screws During operational use the AuditorTorque Cube is subjected to rotational forces that require 2 points of attachment to the work station to secure against Dowel pins of at least 2 50 mm may also be used at the work station wh...

Page 4: ...or use with a serial printer or Windows PC device Dimensions 3 125 79 375 mm Wide 3 75 95 25 mm High 3 23 82 55 mm Deep 2 5 lb 1 13 kg Power Requirements 9 26V DC 150 mA min Supplied by 100 220VAC Input Transformer Battery Internal non field serviceable NiMh pack 32 F 0 C to 122 F 50 C Data Communications RS 232 Accuracy 1 of Indicated Reading within top 90 of Full Scale Range 10 to 100 of Full Sca...

Page 5: ...the same direction a simulated hard joint is achieved Fig B Alignment of the concave shapes in an opposing manner a simulated soft joint is achieved Fig C Differing combinations allow for simulated medium joints to be achieved Fig D Fig A Fig B Fig C Fig D Prior to use remove the Joint Simulator from its bag Loosen the Hex Screw and stack the Bellville Washers according to your joint condition nee...

Page 6: ...gh the available units Kgf M Kgf Cm gf Cm Ncm Nm FT LB IN LB IN OZ Pressing any other key will return to SAMPLE mode ENT Pressing ENT will send the current reading to the serial port and clears the screen MDE ENG Pressing MDE ENG buttons simultaneously displays the Program Menu See Program Menu section for details ACTIVE DISPLAY Active Display Mode is the normal operating mode used by the Auditor ...

Page 7: ...st shown setting will be held PPER PEAK BLANKING Minimum peak as a percentage of full scale Readings below the SET value will not be displayed Settings in the range of 2 50 are available Pressing ENT will sequentially increase the by one with each press At 50 the unit will scroll back to 2 with the next press of ENT After 5 seconds of no changes the unit will revert to Active Display Mode and the ...

Page 8: ...ers 1 20 Pressing ENT at the number 20 scrolls the menu selection back to OFF After 5 seconds of no changes the unit will revert to Active Display Mode and the last shown setting will be held The internal battery pack contained in the Auditor Torque Cube is non user serviceable When treated properly the battery pack should provide approximately 12 hours of continuous use from a full charge The bat...

Page 9: ... RS232 cable enabling connection to a seRial printer data collector computer or other RS 232 enabled device Values are sent via RS 232 each time the unit Auto Clears AC or the ENT or CLR buttons are pressed RS 232 Transfer Protocol Protocol Value Cable P N RS232C Mini Plug Auditor CUBE Dsub 9 Pin Baud Rate 9600 Parity None Bits 8 Stop Bit 1 Flow None RS 232 Data Stream Format Mmmbsdddddbuuuuucl wh...

Page 10: ...set level HIGH LIMIT Use the High Limit setting as a means of visually alerting the operator when a reading is above a desired maximum value The RED LED will illuminate to let the operator know that the achieved reading was above the preset level CAL For factory authorized service center use only NEW TOOL AND ACCESSORY WARRANTY Any new tool or accessory branded withtheAIMCO Uryu AcraDyne or Eagle ...

Page 11: ...es the right to make these changes without incurring any obligation or incorporating such changes or updates in tools or parts previously distributed THE AIMCO WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND AIMCO EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS WARRANTY SETS FORTH THE SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT STRIC...

Page 12: ... MEXICO SA DE CV 10000 SE Pine Street Ave Cristobal Colon 14529 Portland Oregon 97216 Chihuahua Chihuahua 31125 Phone 503 254 6600 Mexico Toll Free 1 800 852 1368 Phone 01 614 380 1010 Fax 01 614 380 1019 LIT MAN920 Rev 07 2020 Printed in USA 2020 AIMCO ...

Reviews: