background image

PAGE HEADER HERE

GEN III 2000 SERIES TUBENUT RUNNERS 

 ITEM # 

AET 

AET 

AET 

AET 

 

QTY. 

PART # 

DESCRIPTION

  

32020A 32025A  32035A 32050A

 

1 X X  X X 

 

1 25064 

MOTOR 

HOUSING

 

 

25425 

MOTOR ASM., 5:1, 2000 SERIES GEN III

 

 

25063 

LED BOARD ASM.

 

 

25075 

SCREW, SHC 4-40X.375, STEEL, BLACK OXIDE

 

 

25429 

STAND-OFF, LED, 2000 SERIES

 

 

25073 

SCREW, SET 4-40X.375, STEEL, BLACK OXIDE

 

7 X X  X X 

 

1 24254 

SPACER, 

PILOT

 

 

25298 

SPIRAL RETAINING RING

 

 

21122 

TUBENUT ADAPTOR ASSEMBLY

 

10 X X  X X 

 

2 24272 

ADAPTOR 

INSERT

  11 

 

24324 

DOWEL PIN 3/32 Dia x 7/8 LONG

  12 

 

25418 

TOOL CONNECTOR ASM GEN III TOOLS

  13 

 

25271 

SHIM. - .002

  14 

 

25272 

SHIM. - .005

  15 

 

25273 

SHIM. - .010

  16 

 

25102 

Screw, BHC4-40X.188, STEEL, BLACK OXIDE

  17 

 

25402 

T.I.D. BOARD ASM. - GEN III

  18 

 

24934 

FLAT HEAD CAP SCREW

 

19 X X  X X 

 

1 25071 

SPRING, 

LEVER

 

20 X X  X X 

 

1 25074 

LEVER 

ASSEMBLY

 

21 X X  X X 

 

2 20061 

SCREW, 

LEVER

  22 

 

25072 

O-RING, LED LIGHT RING COVER

  23 

 

20534 

3000 SERIAL/MODEL LABEL

  24 

 

25058 

LIGHT RING COVER, LED

  25 

 

25060 

HANDLE COVER, REV. BUTTON

 

26 X X  X X 

 

1 24679 

RETAINING 

RNG

  27 

 

24683 

SPRING, REV BUTTON

  28 

 

24706 

REV BUTTON SUB-ASSEMBLY

 

29 X X  X X 

 

1 25059 

HANDLE 

COVER

  30 

 

10 

24940 

SCREW, FHSC 4-40 X .25 LG., STEEL, BLACK OXIDE

 

31 X X  X X 

 

1 21748 

LOCK 

NUT

  32 

 

 

 

 

21631 

TUBENUT HEAD ASM. 

  

 

 

 

 

21632 

  

 

 

 

 

21633 

  

 

 

 

 

21634

 

33 X X  X X 

 

1 22141 

SAFETY 

LABEL

7

2

8

3

4

11

6

30

17

29

16

24

15

14

13

22

25

1

28

27

19

20

26

21

23

33

9

30

10

18

31

32

5

12

Assembly for: AET32020A, AET32025A, AET32035A and AET32050A

4

Summary of Contents for AcraDyne Gen III 2000 Series

Page 1: ...PO Box 16460 Portland OR 97292 0460 800 852 1368 Fax 800 582 9015 www aimco global com AcraDyne Gen III 2000 Series Tubenut runners Operations Manual ...

Page 2: ... such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries If the maximum duty cycle of the attached tool is exceeded or the tool temperature exceeds 50 C then the operator should wear protective hand wear gloves c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools wit...

Page 3: ...counter clockwise operation mode REV The MFB is the small button opposite the trigger The tool will initially start in clockwise mode and will have no LED lights turned on If the trigger is pressed the tool will turn on the blue LED meaning the tightening operation is underway Pressing the MFB will cause the tool to flash yel low and red LED lights Pressing the MFB again will switch the tool back ...

Page 4: ... X X 1 25273 SHIM 010 16 X X X X 1 25102 Screw BHC4 40X 188 STEEL BLACK OXIDE 17 X X X X 1 25402 T I D BOARD ASM GEN III 18 X X X X 2 24934 FLAT HEAD CAP SCREW 19 X X X X 1 25071 SPRING LEVER 20 X X X X 1 25074 LEVER ASSEMBLY 21 X X X X 2 20061 SCREW LEVER 22 X X X X 1 25072 O RING LED LIGHT RING COVER 23 X X X X 1 20534 3000 SERIAL MODEL LABEL 24 X X X X 1 25058 LIGHT RING COVER LED 25 X X X X 1 ...

Page 5: ...of 120 RMS or 320 Volts Pulse DC Controller Supply Voltage of 230 RMS Duty Cycle The Nutrunner tools are intended for intermittent operation with recommended maximum duty cycles not to exceed 33 Note actual maximum duty cycles are dependant upon several factors including Ambient Temperature Tool selection Joint conditions fastening parameter programming anddifferent applications and strategies For...

Page 6: ...etting this value too high can cause the socket to snap back to the home stop too quickly and potentially damage the tool Units lbf in approximation TID memory location 54 Typical Procedure for Setting the Tool s Tube Nut Home TID Parameters Set the Hold at Home Torque 0 Set the Home Detection Torque 1 Free run the tool and watch the homing routine while making the adjustments below Gradually incr...

Page 7: ...Decreasing this can reduce the impact force when hitting the home stop Attention Care must be taken increasing the speed above the default value Too high of a value can greatly in crease how hard the output will hit the home stop and potentially damage the tool Units RPM of the tool output socket in the homing direction Default value 100 RPM Range 1 to 200 RPM Tube Nut Homing Acceleration Rate at ...

Page 8: ...reliably detect an obstruction GEN III Controller Parameters Affecting Tube Nut Pinch Detection Controller parameters for soft start operation can be viewed and modified from the Controller Edit Controller Parameter Soft Start in ToolWare Soft Start Dwell Speed The Soft Start Dwell Speed is used during the check for obstructions Decreasing this can reduce the impact force when hitting an obstructi...

Page 9: ...10 Tube Nut Homing Start Input Logic Selection The controller parameters for tube operation can be viewed and modified from the Controller Edit Controller Parameter Tube Nut screen in ToolWare Tube nut Home Strategy Lever action required to start the home sequence Options Home on release and repress of the lever default Home on release of the lever GEN IV Controller Parameters Affecting Tube Nut P...

Page 10: ...NOTES 10 ...

Page 11: ...NOTES 11 ...

Page 12: ...MEXICO SA DE CV 10000 SE PINE STREET AVE CRISTOBAL COLON 14529 PORTLAND OREGON 97216 CHIHUAHUA CHIHUAHUA 31125 PHONE 503 254 6600 MEXICO TOLL FREE 1 800 852 1368 PHONE 01 614 380 1010 FAX 01 614 380 1019 LIT MAN164 REV 07 2020 PRINTED IN USA 2020 AIMCO ...

Reviews: