7
•
Tube Nut Homing Reverse Dwell Time:
- The amount of time before the output is allowed to home, after the rundown is complete and the tool lever is re-
leased.
-
Units: Seconds
- Default value: 0.5 Seconds
- Range: 0 to 2 Seconds
•
Tube Nut Home Dwell time:
- The amount of time the tool holds at home to prevent bounce back
- Too short of home dwell time can increase the occurrence of bounce back. However, decreasing the homing speed
can decrease the severity of bounce back after the home stop is reached and allow for a shorter dwell time.
- Units: Seconds
- Default value: 0.5 Seconds
- Range: 0 to 2 Seconds
geN IV c
oNTroller
p
arameTers
a
ffecTINg
T
ube
N
uT
H
omINg
Controller parameters for tube-nut operation can be viewed and modified from the Controller->Tool Setup->Disassembly and
Tube-nut screen.
•
Tube Nut Homing Max Speed:
- This is the speed the tool output socket travels when returning to the home position.
- Decreasing this can reduce the impact force when hitting the home stop.
- Attention: Care must be taken, increasing the speed above the default value. Too high of a value can greatly in-
crease how hard the output will hit the home stop and potentially damage the tool.
- Units: RPM of the tool output socket in the homing direction
- Default value: 100 RPM.
- Range: 1 to 200 RPM
•
Tube Nut Homing Acceleration:
- Rate at which the speed of the tool ramps to the homing speed.
- Units: kRPM/second
- Default value: 0.5
- Range: 0.1 to 10
•
Tube Nut Homing Reverse Dwell Time:
- The amount of time before the output is allowed to home, after the rundown is complete and the tool lever is re-
leased.
- Units: Seconds
- Default value: 0.5 Seconds
- Range: 0 to 2 Seconds
•
Tube Nut Home Dwell time:
- The amount of time the tool holds at home to prevent bounce back
- Too short of home dwell time can increase the occurrence of bounce back. However, decreasing the homing speed
can decrease the severity of bounce back after the home stop is reached and allow for a shorter dwell time.
- Units: Seconds
- Default value: 0.5 Seconds
- Range: 0 to 2 Seconds