- Units: RPM of the tool output
- Default: 90 RPM
- Range: 1 to 200 RPM
- Obstruction Check Acceleration Limit
- Rate at which the speed of the tool ramps to Obstruction Check Speed.
- Units: kRPM/second
- Default value: 0.5
- Range: 0.1 to 10
T
ube
N
uT
H
omINg
s
TarT
I
NpuT
l
ogIc
s
elecTIoN
:
The controller parameters for tube- operation can be viewed and modified from the Controller->Edit Controller Parameter-
>Tube Nut screen in ToolWare.
•
Tube nut Home Strategy:
- Lever action required to start the home sequence.
- Options:
Home on release and repress of the lever (default)
Home on release of the lever
geN IV c
oNTroller
p
arameTers
a
ffecTINg
T
ube
N
uT
p
INcH
D
eTecTIoN
(c
oNT
’
D
)
Summary of Contents for AcraDyne Gen III 2000 Series