2. Installation
ANET1553-x
User’s Manual
10
2.2.2.3 Powering the module
In general any external power supply which is providing the specified input voltage (see
Technical Data chapter) can be used to power the module.
An external 12V
DC
power supply is recommended and is provided with an ANET1553
module. All onboard voltages are generated from this voltage.
Power Up behaviour:
- when applying external power for the first time, the module will start up w/o
requiring an explicit power button press.
- as long as the external power supply is present, the module can powered down
(shutdown) and powered up via pressing the power button.
- Interrupting the external power or pressing the power button longer than
3 seconds, will force a power off without shutdown (power down) of the OS.
Note: It is recommended, but not mandatory, to shutdown (power down) the module
via the power button or the ANET web front (‘maintenance’ page) end or SSH
shell command (‘power off’ as user ‘root’) to avoid any user data corruption,
especially when having customer applications/scripts active on the module.
Summary of Contents for ANET1553 Series
Page 2: ......
Page 6: ...ANET1553 x User s Manual iv THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 40: ...3 Getting started ANET1553 x User s Manual 30 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 56: ...7 Frequently asked questions ANET1553 x User s Manual 46 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 60: ...8 Technical Data ANET1553 x User s Manual 50 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 62: ...9 Notes ANET1553 x User s Manual 52 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 64: ...10 Apendix ANET1553 x User s Manual 54 THIS PAGE INTENTIONALLY LEFT BLANK ...