9.7 Setting to Factory Defaults
Menu > Factory Defaults
This function can be used to return most of the instrument settings including Voltage, Current,
Range, OVP, OCP, Output On/Off, Current Meter Averaging, Multi-On/Off Action and System
Preferences back to the factory default values as listed in section 18. Note that it is possible
that a request to set factory defaults will fail to complete if it invokes certain range changes, see
section 7.6 for more information.
The Store memories for both individual outputs and All Outputs are unaffected. To clear each
bank of Stores it is necessary to use the function Stores > Delete > Del All.
LCD contrast setting and remote interface settings (MX180TP only) are also unaffected.
9.8 Adjusting LCD Contrast
Menu > Adjust LCD Contrast
The LCD contrast can be adjusted over a wide range. The setting is displayed numerically as a
percentage. The display can also be inverted from black on white to white on black.
9.9 Calibration
Menu > Calibration
The Calibration function enables the instrument to be re-calibrated when required.
Calibration will overwrite the existing settings and should only be carried out by qualified
personnel in conjunction with the instrument Service Guide and the necessary precision
equipment.
A 4-digit pass code can be set to prevent unauthorised calibration if required.
9.10 Remote Control Interfaces (MX180TP only)
Menu > Remote Control Interfaces
Settings for the GPIB and LAN interfaces can be observed using this function.
Details for the GPIB interface are within the Remote Interfaces Configuration section 12.2.1.
Details for the LAN interface are within the Remote Interfaces Configuration section 12.2.4.