background image

10

11

aidacare.com.au

Code

Description

BEB046520

Folding Assist Bar

BEB046525

Split Folding Side Rails (Pair)

BEB046530

IV Pole

BEB046540

Self Help Pole

BEB046590
BEB046592

Battery Backup

BEB046616

USB Port Upgrade Kit

5. ACCESSORIES

A range of FL250 Bed accessories are available. In addition to the below listed 

accessories, Aidacare specialises in other complimentary products such as foam 

mattresses, pressure care surfaces, over bed tables, side lockers and adjustable 

day chairs. Please contact Customer Service on 1300 133 120 for further information.

Code 

Description

BEA030050

EasyMove Transport System 

*Does not include bed shown 

BEB046200
BEB046220

Bed End Set – Single – Tahoe – Teak
Bed End Set – King Single – Tahoe – Teak

BEB046210
BEB046230

Bed End Set – Single – Vail – Milano
Bed End Set – King Single – Vail – Milano

BEB046240
GSP391630
GSP391640

Bed Side Set – Tahoe – Teak
Mounting Hardware – Single
Mounting Hardware – King Single

BEB046250
GSP391630
GSP391640

Bed Side Set – Vail – Milano 
Mounting Hardware – Single
Mounting Hardware – King Single

BEB046500

Width Extension Kit

WARNING

Do not use accessories that have not been designed for use  

with FL250 Beds.

Summary of Contents for BEB046100

Page 1: ...FL250 FLOORLINE BED USER MANUAL...

Page 2: ...manual carefully before using your new bed TABLE OF CONTENTS Symbols Used In This Manual 4 Introduction 5 2 Safety Precautions 6 3 Overview 8 4 Specifications 9 5 Accessories 10 6 Electronic Functions...

Page 3: ...angle maximum 35 Bi lateral mattress retainers with length adjustable mattress extension retainer at foot end Integrated foot end extension Extends the bed by 100mm or 200mm Large range of feature en...

Page 4: ...tem must be reset when any changes are made to it Changes are defined as mains power is lost power outage turned off on mains cable is unplugged component cabling is disconnected from or connected to...

Page 5: ...rade IP54 Standards Compliance Aidacare FL250 Beds are designed and manufactured where required in compliance with International Medical Device Safety standard IEC60601 1 IEC60601 2 52 All electronics...

Page 6: ...day chairs Please contact Customer Service on 1300 133 120 for further information Code Description BEA030050 EasyMove Transport System Does not include bed shown BEB046200 BEB046220 Bed End Set Singl...

Page 7: ...button is pressed Adjustment will stop when the button is released or the selection reaches the end of its range Auto Contour Conveniently positions patient into cardiac chair position for therapeutic...

Page 8: ...Adjustable Mattress retainer 1 x Wall Buffer 1 x Handset 1 x Set of 2 Head Board Holders short 2 Foot Board Holders long 1 x Head Board Sold Separately 1 x Foot Board Sold Separately WARNING The FL250...

Page 9: ...cord out as desired d Tighten cable gland to lock cable in place e Test bed through both its hi lo and backrest movement range and ensure the power cord does not get pinched or crushed by the frame An...

Page 10: ...s pre stamped locator points insert the shaft into the bed frame until you feel or hear a click which is the bed frame lining up with the shaft locator point 18 Fasten each Holder at the locator point...

Page 11: ...ch as forklift walkie stacker pallet jack hydraulic lift trolley etc lower the bed carton to 600 700mm from the ground 2 Carefully remove strapping and external dunnage materials remove the carton lid...

Page 12: ...ght 4 Line up the Head Board Bracket Pegs with the Head Board Holder keyholes 5 Insert ensuring both sides are fully inserted push the Head Board down so the pegs drop into the bottom of the Holder ke...

Page 13: ...1 x FOOT section LEFT second longest unique to this section and side 1 x FOOT section RIGHT second longest unique to this section and side Item 2a Hardware for Single Bed 18 x Attachment Bolts and Wa...

Page 14: ...mount the SHP on left or right 5 Undo the left or right Head Board attachment bracket screws and remove the outside plate 6 Position the SHP attachment and receiver bracket over the Head Board holes...

Page 15: ...cers NOTE If Side Panels are already fitted to the single bed they must be removed before the King Single Conversion Kit can be attached Recommended Tools Power Drill Right Angled Power Drill Adaptor...

Page 16: ...nded Tools Power Drill Right Angled Power Drill Adaptor Fastening Folding Assist Bar to Bed 1 For best access to the bed frame side to attached the Folding Assist Bar use the FL250 EasyMove Transport...

Page 17: ...owards the foot end of the bed as shown 4 Remove the 3 x bolts bushes and dome nuts from the mounting plate 5 If mounting to a King Single bed use the bushes supplied For a single bed only the bolts a...

Page 18: ...ocate and unclip the cover exposing existing leads connected to ports and spare port 6 Position the battery back up lead so the groove is aligned with the spare port and insert fully into port 7 Reatt...

Page 19: ...ally so the safety clip is to the right of the quick release axle 9 Lower the bed until the bed frame axle mount is level with the quick release axle on each EasyMove trolley 10 While pressing the qui...

Page 20: ...e 26 If more than one hand is required there is likely to be an encumbrance on the pivot motion please check around the bed 27 When the bed frame is vertical re engage the pivot locks by pulling and t...

Page 21: ...cable to beds with serial number prior to FL250 V2 2204 24505 4 Assemble USB port to the underside of the backrest using the mattress retainer legs as studs and secure in place with handwheels bed ser...

Page 22: ...ort functions correctly Ensure cables have enough slack to accommodate all deck panel movements 13 Ensure cables are secured in place and protected from any moving parts of the bed Zip tie excess cabl...

Page 23: ...s designed for use as a bed extension only and is not meant to support the body weight of a person sitting The extra length of the bed with extra load can also make the bed unstable potentially result...

Page 24: ...leaning NOTE For easy access to all parts of the bed and for safe handling use the EasyMove Transport System NOTE The following procedure also applies to bed accessories but does not include mattresse...

Page 25: ...the control box should always be reset to rule out any calibration issues Calibration issues can occur when power outages happen or when beds are unplugged from the wall during use To complete a reset...

Page 26: ...cts where any original components have been changed or modified by non Aidacare approved and trained service maintenance staff or external providers Furthermore safety is not guaranteed where componen...

Page 27: ...ABUM10 61 281122 AIDACARE PTY LTD Building 3A 1 Moorebank Avenue Moorebank NSW Australia 2170 1300 133 120 aspirecare com au MADE IN PRC...

Reviews: