Chapter 9 - Emergency Operation
40
06-22
Emergency pump switch
fig. 9-4
(1) Press the emergency pump switch.
(2) The pump will turn on when both
the emergency pump switch and the
operation switch are turned on.
(3) If work is being done on a high place, and
it happens that the machine is inoperable
because of engine or pump trouble,
use the emergency pump to lower the
operator to the ground.
(4) The emergency pump runs off the battery.
(5) The emergency pump work cycle
M082M420
30 seconds
or less
30 seconds
or more
Pause
Operate
Pause
Operate
30 seconds
or less
30 seconds
or more
fig. 9-5