3 Product description
3.1 General information
AHT products meet the requirements of the EU directive 1907/2006 (REACH) concerning the regis-
tration, evaluation, authorisation and restriction of Chemicals. In the product design, the manufac-
turer has considered the environmental and disposal friendliness of the units.
Neither the refrigerant R-290 nor the propellant pentane (for the insulating foam) have an Ozone
Depletion Potential (ODP).
R-290 has a very low Global Warming Potential ( (GWP) of 3.
3.2 Technical data
Important technical data can be found on the serial plate (see →Serial plate and serial number).
– Externaldimension
– Maximum tota weight unit
See →Model types-overview
Airborne noise emissions
Emission sound pressure level < 70 dB(A)
Maximum load on storage racks
See →following table and →Loading
Storage rack
Maximum load
[kg]
[lb]
Display shelf (shelf) or
floor plate / floor shelf
30
66.14
Technical interfaces
Power supply (unit-specific, observe the specifica-
tions on the serial plate see →Serial plate and serial
number)
Connector-types
Unit
110-120V 60Hz
NEMA 5-15P
Minimum requirement unit-connection cable
14AWG
Electrical fuse protection
(see →Electrical protection)
Electrical fuse
protection
Rated current
[A]
Trip characteris-
tic
Type
Triggering
current [mA]
for 110-120V
Circuit braker
(LS/CB)
15
C (time-lag)
-
-
Residual current
circuit breaker
(FI/RCCB/GFCI)
40
_
surge current strength
short-time delayed
e.g. G/AP-R
30
Combination
switch FI-LS/
RCBO
15
C (time-lag)
surge current strength
short-time delayed
e.g. G/AP-R
30
Customized deviations possible.
Further information: Maintenance services (see →Maintenance services).
3.3 Serial plate and serial number
When handling the unit, the information on the serial plate must be observed.
The serial plate is located on the rear side of the unit (outside) and contains important technical
data about
– Unit name and unit type
– Serial number
– Climate class* (see →Intended use)
– Nominal voltage and nominal frequenc
– Nominal current and nominal consumption
– Refrigerant and quantity
– Net volume
– Date of production
– Certification marks
– Further technical data
*Examples for climate classes: