1.800.627.4499
4
Subject to change without notice:
RENEWAIRE.COM
| 1.800.627.4499
5
4
Subject to change without notice:
RENEWAIRE.COM
| 1.800.627.4499
SPECIFICATIONS & DIMENSIONS
RenewAire LLC
SCALE:1:40
SIZE
DWG. NO.
A
MATERIAL:
FINISH:
SEE BILL OF MATERIAL
DO NOT SCALE DRAWING.
REMOVE ALL BURRS, BREAK
SHARP EDGES.
APPLICABLE STANDARDS: DIM.
AND TOL. ANSI Y14.5
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES:
LINEAR 0.015
HOLE SIZE 0.005
ANGULARITY 3
SURFACE FINISH =
63 MICROINCH MINIMUM
DATE:
DRAWN BY:
ZWP
11/09/18
SK6700_003
SHEET 3 OF 3
201 Raemisch Rd.
Waunakee, WI 53597 USA
TEL: (608) 221-4499
FAX: (608) 221-2824
TOLL FREE: (800) 627-4499
TITLE:
CHECKED BY:
DATE:
--
--
APOLLO 3X4 NAPLES COMMUNITY
LEVEL DESCRIPTION OF REVISION
DATE
BY
003
02/14/19 ZWP
FINAL RELEASE.
---
SEE BILL OF MATERIAL
CABINET PROVIDED BY OTHERS.
FOR REFERENCE ONLY.
SPECIFICATIONS
Ventilation Type:
Static plate, heat and humidity transfer
AHRI 1060 Certified Core:
L125-G5 (Quantity varies)
SERIES
SA
Energy Recovery Core Array
AIRFLOW PERFORMANCE
3-high
5-high
7-high
0.0
0.5
1.0
1.5
2.0
0
200
400
600
800
1000
1200
Pr
essu
re
Dr
op
(i
n.
w.
g.)
Airflow per Core (SCFM)
SA Series Pressure Drop Rating per Core
Standard Features:
SA-Series units can be configured from 3H3W to 8H8W
Blower not included and must be specified to meet
job requirements.
Choice of airflow configuration: parallel flow, crossflow
Plenum assembly
Knockdown shipping only
Insulated dividers between airstreams
SAIN
Crossflow
SAIN
Parallel flow
Can be configured on site.
Available as shown:
AIRFLOW ORIENTATION
INDOOR UNIT
Stackable Array
NEW
When parallel flow airflow orientation is used, flow is not optimally distributed to every
exchanger and performance is slightly reduced. In this case the sensible and latent effective-
ness must be derated by the amount shown in the EFFECTIVENESS DERATE chart. This derate is
automatically applied by CORES.RenewAire.com (v1.3.0 and after) when parallel flow orientation
is selected.
EFFECTIVENESS SUBTRACTION DERATE
FOR PARALLEL FLOW
3-high
4-high
5-high
6-high
7-high
8-high
-3.0%
-2.5%
-2.0%
-1.5%
-1.0%
-0.5%
0.0%
0
200
400
600
800
1000
1200
Effect
ive
ness D
erate
(%
p
oi
nts)
Airflow per Core (SCFM)
Effectiveness Derates for Straight-Through Flow
SAIN
Parallel flow
APPLICATION
ELEVATION
PLAN
RenewAire LLC
SCALE:1:65
SIZE
DWG. NO.
A
MATERIAL:
FINISH:
SEE BILL OF MATERIAL
DO NOT SCALE DRAWING.
REMOVE ALL BURRS, BREAK
SHARP EDGES.
APPLICABLE STANDARDS: DIM.
AND TOL. ANSI Y14.5
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES:
LINEAR 0.015
HOLE SIZE 0.005
ANGULARITY 3
SURFACE FINISH =
63 MICROINCH MINIMUM
DATE:
DRAWN BY:
ZWP
11/09/18
SK6700_003
SHEET 2 OF 3
201 Raemisch Rd.
Waunakee, WI 53597 USA
TEL: (608) 221-4499
FAX: (608) 221-2824
TOLL FREE: (800) 627-4499
TITLE:
CHECKED BY:
DATE:
--
--
APOLLO 3X4 NAPLES COMMUNITY
LEVEL DESCRIPTION OF REVISION
DATE
BY
003
02/14/19 ZWP
FINAL RELEASE.
---
SEE BILL OF MATERIAL
END
CABINET PROVIDED BY OTHERS.
FOR REFERENCE ONLY.
SA SERIES AIRFLOWS CAN BE
CONFIGURED ON SITE. AIRFLOWS
CAN BE CROSSFLOW OR PARALLEL
FLOW.
Energy Recovery Core is AHRI Certified
®