Ga
s S
up
ply
IMPORTANT:
Any additions, changes or conversions re-
quired for the furnace to satisfactorily meet the application
should be made by a qualified installer, service agency or
the gas supplier, using factory-specified or approved parts.
IMPORTANT:
Connect this furnace only to gas supplied by
a commercial utility or commercial fuel provider.
IMPORTANT:
U.L. or CSA recognized fuel gas and carbon
monoxide (CO) detector(s) are recommended in all appli-
cations, and their installation should be in accordance with
the manufacturer’s recommendations and/or local laws,
rules, regulations or customs.
Install the gas piping according to all local codes and regu-
lations of the utility company.
If possible, run a separate gas supply line directly from the
meter to the furnace. Conventional and alternate gas in-
stallations are detailed in Figure 30. Alternate gas from
right of cabinet will require additional fittings. Two street el-
bows are recommended to route gas line behind the valve
and align the knockout in the furnace casing.
NOTE: *FOR
Canadian installations only
corrugated stainless steel
tubing (CSST) can be used for alternate gas routing inside
the cabinet. A connection from CSST to solid black iron
pipe must be made before exiting the cabinet. Ensure pipe
passes through the grommet and the grommet seats prop-
erly in the cabinet side for proper furnace operation. Con-
sult the local gas company for the location of the manual
main shut-off valve.
The gas line and manual gas stop
must be adequate in size to prevent undue pressure
drop and never smaller than the pipe size to the gas
valve on the furnace.
Refer to Table 11 for natural gas
(Table 12 for LP gas) for the recommended gas pipe size.
See Figure 30 for typical gas pipe connections.
Install a ground joint union within 3 feet of the cabinet
to easily remove the gas valve assembly. Local codes
may dictate the location of the ground joint union. In-
stall a manual shut-off valve in the gas line outside of
the furnace casing and upstream of the ground joint
union.
The manual shut-off valve should be readily acces-
sible to turn the gas supply on or off. Install a drip leg in
the gas supply line as close to the furnace as possible. Al-
GAS SUPPLy
GAS PIPING
FIGURE 30
GAS PIPING INSTALLATION
!
WARNING
THIS FURNACE IS EqUIPPED AT THE FACTORy
FOR USE ON NATURAL GAS ONLy. CONVERSION
TO LP GAS REqUIRES A SPECIAL kIT IS AVAIL-
ABLE AT THE DISTRIBUTOR. FAILURE TO USE THE
PROPER CONVERSION kIT CAN CAUSE FIRE,
CARBON MONOxIDE POISONING, ExPLOSION,
PROPERTy DAMAGE, PERSONAL INJURy OR
DEATH. SEE THE CONVERSION kIT INDEx SUP-
PLIED WITH THE FURNACE. THIS INDEx IDENTI-
FIES THE PROPER LP GAS CONVERSION kIT
REqUIRED FOR EACH PARTICULAR FURNACE.
UPFLOW
45
ST-A1205-07-02
Summary of Contents for (-)98VA060M317USA
Page 12: ...Field Conversions FIELD CONVERSIONS 12 ...
Page 13: ...FIELD CONVERSIONS Field Conversions 13 SEE NExT PAGE FOR APPLICABLE CONFIGURATIONS ...
Page 15: ...Field Conversions 15 ...
Page 16: ...Field Conversions ST A1194 68 00 16 ...
Page 17: ...Field Conversions 17 ...
Page 18: ...Field Conversions 18 ...
Page 92: ...92 Diagnostics TABLE 19 R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 93: ...93 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 94: ...94 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 95: ...95 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 96: ...96 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 97: ...97 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 98: ...98 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 99: ...99 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 100: ...100 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 101: ...101 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 105: ...105 FIGURE 67 MODULATING ECM FURNACE WIRING DIAGRAM Troubleshooting ...
Page 106: ...106 ...
Page 107: ...107 ...
Page 108: ...108 CM 0717 ...