GENERAL INFORMATION
10
1
11
12
13
14
16
24
7
8
9
23
6A
5
2
4
3
22
25
20
21
19
18
5
17
15
26
6B
6C
ITEM
NO. DESCRIPTION
1.
CONDENSATE TRAP
2.
DOOR SWITCH
3.
JUNCTION BOX
4.
TRANSFORMER
5.
WATER SENSOR (2)
6.
PRESSURE SWITCH STAGES
A. HIGH
B. MEDIUM
C. LOW
7.
EXHAUST TRANSITION
8.
COUPLING (ELBOW TO TRANSITION)
9.
EXHAUST
10.
SHIPPING PLUG
11.
FLAME SENSOR
12.
OVER TEMPERATURE SWITCH
13.
TOP PLATE
14.
BURNER
15.
IGNITER
16.
COMBUSTION AIR INLET
17.
GAS VALVE
18.
INDUCED DRAFT BLOWER (IDB)
19.
POWER FACTOR CORRECTION CHOKE
(PFC) (NOT USED ON THE 60K BTU
AND 70K BTU)
20.
CONTROL MOUNTING PLATE
21.
BLOWER
22.
LOW VOLTAGE TERMINAL
23.
COUPLING (IDB TO ELBOW)
24.
MAIN LIMIT
25.
FURNACE CONTROL
26.
AUXILIARY TRAP
ST-A1194-67-00
FIGURE 1
FURNACE COMPONENTS
NOTE:
A heat loss calculation should be performed to
properly determine the required furnace BTU size for the
structure. Also, the duct must be properly designed and in-
stalled for proper airflow. Existing ductwork must be in-
spected for proper size and to make sure that it is properly
sealed. Proper airflow is necessary for both user comfort
and equipment performance.
Before opening the furnace carton, verify that the data
tags on the carton specify the furnace model number
that was ordered from the distributor and are correct
for the installation. If not, return the unit without open-
ing the carton. If the model number is correct, open
the carton and verify that the furnace rating label
specifies the same furnace model number that is
specified on the carton label. If the model numbers do
not match, return the furnace to the distributor.
IMPORTANT:
Proper application, installation and mainte-
nance of this furnace and system is a must if consumers
are to receive the full benefits for which they have paid.
The (-)98V series furnaces are design-certified by CSA for
use with natural and propane gases as follows:
1. As non-direct vent central forced air furnaces taking
combustion air from the installation area or using air
ducted from the outside.
2. As direct vent central forced air furnaces with all com-
bustion air supplied directly to the furnace burners
through a special air intake system outlined in these
instructions.Install this furnace in accordance with the
American National Standard Z223.1 – latest edition
entitled “National Fuel Gas Code” (NFPA54) or, for
Canada, CSA B149.1; Canadian Natural Gas and
Propane Installation Code and requirements or codes
of the local utilities or other authorities having jurisdic-
tion. This is available from the following:
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
CSA-INTERNATIONAL
5060 Spectrum Way
Mississauga, Ontario
Canada L4W5N6
Online: www.csa.ca
3
Summary of Contents for (-)98VA060M317USA
Page 12: ...Field Conversions FIELD CONVERSIONS 12 ...
Page 13: ...FIELD CONVERSIONS Field Conversions 13 SEE NExT PAGE FOR APPLICABLE CONFIGURATIONS ...
Page 15: ...Field Conversions 15 ...
Page 16: ...Field Conversions ST A1194 68 00 16 ...
Page 17: ...Field Conversions 17 ...
Page 18: ...Field Conversions 18 ...
Page 92: ...92 Diagnostics TABLE 19 R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 93: ...93 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 94: ...94 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 95: ...95 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 96: ...96 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 97: ...97 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 98: ...98 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 99: ...99 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 100: ...100 Diagnostics TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS ...
Page 101: ...101 TABLE 19 continued R98V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics ...
Page 105: ...105 FIGURE 67 MODULATING ECM FURNACE WIRING DIAGRAM Troubleshooting ...
Page 106: ...106 ...
Page 107: ...107 ...
Page 108: ...108 CM 0717 ...