13
Item
Range
Default
Value
Access Level
Description
Set Current
Time
12:00A–11:59P
---
User
Selects current time – “A” or “P” will
indicate whether the set time is AM or
PM.
C/F Display
Celsius/Fahrenheit
Fahrenheit User
Selects the units of measure for tem-
perature readings.
Spa Max Temp
65F–104F/18C–40C
104F
User
Selects the maximum Spa tempera-
ture that the control can be adjusted
to in normal operation.
Pool Max Temp
65F–95F/18C–35C
95F
User
Selects the maximum Pool tempera-
ture that the control can be adjusted
to in normal operation.
Pump Periods
0–4
User
Only available if Pump Operation in
the Installer’s Menu is set to “4-
Speed Enabled” or “Variable
Enabled”.
Pump On Time 1
12:00A–11:59P
---
User
Select ON time for Pump Period #1 to
take effect.
Pump Off Time 1
12:00A–11:59P
---
User
Select OFF time for Pump Period #1
to stop.
Pump Speed 1
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Return Valve 1
Pool/Spa
Pool
User
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 1
Pool/Spa
Pool
User
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 2
12:00A–11:59P
---
User
Select ON time for Pump Period #2 to
take effect.
Pump Off Time 2
12:00A–11:59P
---
User
Select OFF time for Pump Period #2
to stop.
Pump Speed 2
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Table C: USER MENU — Heat ONLY, Power Defrost and Heat/Cool Models
NOTE:
The User Menu is exactly the same for Heat
ONLY, Power Defrost and Heat/Cool models.