between the modes. Each press of the MENU but-
ton selects the next mode. There is no automatic
increment from continually pressing the MENU
button. In fact, continually pressing the MENU
button (for 3+ seconds) will move the user into the
USER Menu.
For HEAT ONLY and POWER DEFROST models,
the mode selections are OFF – POOL HEAT –
SPA – TIMED SPA.
10. For HEAT/COOL models, the mode selections are
OFF – POOL COOL – POOL HEAT – POOL AUTO
– SPA – TIMED SPA.
11. REMOTE Mode is accessed by pressing and hold-
ing the UP and DOWN buttons simultaneously for
3 seconds. When exiting the REMOTE mode, the
control always selects the OFF Mode.
12. If the UP, DOWN or MENU buttons are pressed
while in REMOTE mode, the display will read “Exit
Remote Mode to Adjust Temp”. Mode and temper-
ature setpoints are not changed.
13. Press and hold the UP and DOWN buttons for 3
seconds to exit REMOTE Mode.
14. When operating, the unit will continue to operate
until the water temperature is 0.5F above/below
setpoint (below for cooling), until a defrost condi-
tion is needed or the unit is manually turned off.
15. The unit will remain in standby waiting for the next
demand.
Controls
Your heat pump pool heater incorporates digital safe-
ty controls and indicators to ensure its safe, reliable
operation.
Digital Water Temperature Control:
The pool water
temperature is controlled by the heat pump pool
heater’s digital control system, which gives you the
option of two settings: one for the desired spa tem-
perature and the other for the desired pool
temperature. Additionally, as mentioned earlier, the
unit is compatible with most ‘2-wire’ and ‘3-wire’ con-
trol/automation systems.
Digital Controls Operating
Instructions
The electronic board has the capability of memorizing
two different programmed temperature settings as
follows:
• For a pool, maximum 95°F (35°C)
• For a spa, maximum 104°F (40°C)
To Increase or Decrease the Desired Water
Temperature (Pool or Spa Mode)
With the MENU in either Pool or Spa mode, simply
press the UP or DOWN buttons to raise or lower the
setpoint. Holding the UP or DOWN button will incre-
ment the setpoint 1 degree at a time, but continuing
to hold either button will result in a “Speed-Up” mode
which will increase the speed of number changes.
Select Temperature in °C or °F
Press the MENU button for 3+ seconds to enter the
USER Menu. Once in the USER Menu, toggle to the
2nd entry and using either the UP or DOWN buttons,
change the temperature readings into °C or °F.
When complete you can press and hold the MENU
button for 3+ seconds to return to the operating
mode or simply wait and the program will automati-
cally return to the operating mode in 180 seconds.
Heat/Cool Operation
Some models are equipped to provide both heating
and cooling to the pool.
When the unit has been operating in the heating
mode for a few minutes, the discharge air tempera-
ture should be 8°–10°F cooler than the air entering
the unit.
When the unit has been operating in the cooling
mode for a few minutes, the discharge air tempera-
ture should be 8°–10°F warmer than the air entering
the unit.
NOTE:
Heating is more efficient during warmer day-
light hours and cooling is more efficient during cooler
nighttime hours.
NOTE:
Remove the pool/spa blanket and turn on
any fountains, sprays or other water features and
also run your system at nighttime to speed the