15
The Installer/Service menu is used by Installers and Service personnel to set up and troubleshoot the HPPH.
This menu is accessed by pressing and holding the UP and MENU buttons for 3+ seconds.
WARNING: This
menu should never be used by the end user as changes can affect proper operation of the unit.
Table D: INSTALLER/SERVICE MENU — HEAT ONLY Configuration
Item
Range
Default
Value
Access Level
Description
Set Current
Time
12:00A–11:59P
---
Installer
Selects current time – “A” or “P” will
indicate whether the set time is AM or
PM.
Pump Periods
0–4
Installer
Only available if Pump Operation in
the Installer’s Menu is set to “4-
Speed Enabled” or “Variable
Enabled”.
Pump On Time 1
12:00A–11:59P
---
Installer
Select ON time for Pump Period #1 to
take effect.
Pump Off Time 1
12:00A–11:59P
---
Installer
Select OFF time for Pump Period #1
to stop.
Pump Speed 1
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation.
Return Valve 1
Pool/Spa
Pool
Installer
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 1
Pool/Spa
Pool
Installer
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 2
12:00A–11:59P
---
Installer
Select ON time for Pump Period #2 to
take effect.
Pump Off Time 2
12:00A–11:59P
---
Installer
Select OFF time for Pump Period #2
to stop.
Pump Speed 2
1–4 if 4-Speed Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the
selected pump output (which con-
nects to the pump for the selected
speed) for this pump period. On
Variable speed pumps, this denotes
the PWM signal to be provided to the
pump for pump operation
Return Valve 2
Pool/Spa
Pool
Installer
Select the position of a 3-way valve
located between the HPPH and the
Pool/Spa for this scheduled pump
period.
Suction Valve 2
Pool/Spa
Pool
Installer
Select the position of the 3-way valve
located between the Pool/Spa and the
Pump for this scheduled pump period.
Pump On Time 3
12:00A–11:59P
---
Installer
Select ON time for Pump Period #3 to
take effect.