K65C/K75C/K95C
9-1
K65C/K75C/K95C
9-1
Malfunction
Possible cause
Remedy
Engine
See the operating
instructions for the
engine
Engine does
Drive switch (4-12/6) is
Set the drive switch
not start
not in the neutral position
to the neutral position
Generator does
Plug connection is
Push in and secure
not start
loose
the plug connection
V-belt is torn
Replace the V-belt
Generator speed is
Check V-belt tension;
too low
if necessary, tighten
Bucket arm
Pressure relief valve in
Completely dismantle
cannot be raised
the control valve is open
and clean the pressure
or lowered
relief valve; readjust *
Pilot valve for the working
Unlock the pilot valve
and auxiliary hydraulics
(1-3/arrow)
(4-12/5) is locked
Pilot pressure is not
Open the pressure relief
available or is too low
valve in the control line,
clean it and readjust it *
Diesel engine has failed
Using storage pressure,
it is possible to bring the
bucket arm to its lower-
most position directly
after the engine has
failed.
»Not with built-in pipe
break safety device«
Steering requires
Pressure relief valve in
Completely dismantle
increased effort
the steering unit is open
and clean the pressure
relief valve; readjust *
Pusher in the priority valve
Replace the priority
is stuck
valve *
9
Malfunctions, causes and remedies
NOTE
*) Malfunctions may only be remedied by authorised personnel.
Malfunction
Possible cause
Remedy
Engine
See the operating
instructions for the
engine
Engine does
Drive switch (4-12/6) is
Set the drive switch
not start
not in the neutral position
to the neutral position
Generator does
Plug connection is
Push in and secure
not start
loose
the plug connection
V-belt is torn
Replace the V-belt
Generator speed is
Check V-belt tension;
too low
if necessary, tighten
Bucket arm
Pressure relief valve in
Completely dismantle
cannot be raised
the control valve is open
and clean the pressure
or lowered
relief valve; readjust *
Pilot valve for the working
Unlock the pilot valve
and auxiliary hydraulics
(1-3/arrow)
(4-12/5) is locked
Pilot pressure is not
Open the pressure relief
available or is too low
valve in the control line,
clean it and readjust it *
Diesel engine has failed
Using storage pressure,
it is possible to bring the
bucket arm to its lower-
most position directly
after the engine has
failed.
»Not with built-in pipe
break safety device«
Steering requires
Pressure relief valve in
Completely dismantle
increased effort
the steering unit is open
and clean the pressure
relief valve; readjust *
Pusher in the priority valve
Replace the priority
is stuck
valve *
9
Malfunctions, causes and remedies
NOTE
*) Malfunctions may only be remedied by authorised personnel.
Summary of Contents for AL 65
Page 8: ...Safety regulations...
Page 29: ...Signs...
Page 38: ...Technical data...
Page 60: ...Description...
Page 72: ...Operation...
Page 83: ...Attachments...
Page 91: ...Rescue towing lashing lifting by crane...
Page 100: ...Maintenance...
Page 120: ...Malfunctions causes and remedies...
Page 123: ...Protection against theft...
Page 126: ...Appendices...
Page 127: ......
Page 128: ......
Page 131: ......
Page 134: ...K65C K75C K95C K65C K75C K95C B B...
Page 135: ...K65C K75C K95C K65C K75C K95C C C...
Page 136: ...K65C K75C K95C K65C K75C K95C D D...
Page 137: ...K65C K75C K95C K65C K75C K95C E E...
Page 138: ...K65C K75C K95C K65C K75C K95C F F...