17
Error Messages
In this section the possible errors for each PCI 1200 error-messages are listed:
"Max. Retries"
- The wheel does not build pressure.
- Wheel valve connection fault.
- Insufficient tire/rim assembly.
- Compressed air connection blocked or narrowed.
- Errors in the supply of compressed air.
- Too long or too thin air-hoses to and/or from the PCI.
- Compressor fault.
Press “Stop” button, check equipment, airflow and pressure, correct - and retry.
"Above set pressure"
- The tire air pressure is higher than Set Pressure.
- The connection to the wheel valve within 1
st
filling sequence was not optimal.
Press “Stop” button, check and reconnect wheel valve - and retry.
"Set pressure to high"
- The sum of the chosen End pressure and Over-pressure exceeds 7.0 / 12.0 bar.
Press “Stop” button, select and set new values - and retry.
"Gate Open"
- A cage door/gate is open and the tire pressure is above 1.0 bar (measured).
-
The “Door jumper” (Accessory) is missing, defective or not correct mounted.
- The door safety switch or cable-circuit is malfunctioning or damaged.
Press “Stop” button, close the door, check components/equipment, repair - and retry.
"Emergency Stop"
- The
“Emergency Stop Button” (Accessory) has been activated.