12
Start:
Choose one of the four inflation programs; P1 - P4.
Connect the wheel hose with the nipple on the wheel and press the "Start" button.
The inflation sequence cycle begins.
Inflation to the "Set-pressure" (selected End-pr selected overpressure) will follow.
When the “Set-pressure” is reached, the wheel is then deflated until the End-pressure is
reached. The Inflation sequence process can be followed by watching the "status bar"
below the selected and shown End-pressure on the PCI display. In addition, a
triangle/arrow indicates whether the wheel is inflating (arrow up) or deflating (arrow down).
The PCI 1200 adjusts the End-pressure with a typical accuracy of +/- 0.05 bar.
Jet-Functionality:
The PCI 1200 is equipped with a Jet functionality (Orange "Jet" button on the front cover).
It is used with the Omega Jet System in an AHCON TBR 1100 Inflation Cage or AHCON
IT 700/900/1000 Filling Station with compressed air tank.
This system solves the problem that tires and rims do not always fit close together and
therefore it can be difficult or impossible to pressurize the wheel (for instance after tire
change on the rim).
By pressing the "Jet" button, air from the tank is emptied instantaneously through the holes
around the Jet ring. This creates a slight overpressure in the wheel which now will close
the gap between the tire and the rim, and thereby letting air be filled into the wheel.
The "Jet" button is only active for as long as the PCI 1200 has not measured an actual
pressure in the wheel.
Auto Mode (Auto-Start):
The PCI 1200 has an Auto-start functionality.
This can be enabled / disabled in the menu point “Settings” (from software version 1.26).
Add / remove the check-sign; "
√" using the + / - buttons.
Store your choice by pressing the “Menu” button.
If a prefilled wheel with an air-pressure of more than 1.5 bar is connected (2 bar in
software before version 1.26
), the PCI will automatically fill to the earlier preset “End
pressure”.
Notice:
In this case, no overpressure is applied.