CONNECTING POWER
Hazardous voltage. Will cause
serious injury or death. Turn
off the supply electricity at
your facility's circuit breaker
before connecting the saw to
an electrical circuit.
All electrical wiring must be
done by a qualified electrician
in conformance with the
prevailing electrical standards
of your area.
This machine must be
grounded by a qualified
electrician, in conformance
with the NEC “National
Electrical Code” or the
prevailing national, state, and
local electrical codes. Failure
to do so will cause serious
injury or death.
Be sure the supply voltage and
phase matches the voltage the
machine has been wired for.
Refer to the data plate on the
electrical enclosure.
After the coolant pump has been plugged into
the terminal box (see Installing and Wiring the
Coolant Pump in the previous Assembly
section), supply power can be connected to the
saw.
1.
Connect an appropriate grounding wire to
the main panel ground lug.
2.
Remove the three main line fuses 1FU, 2FU
and 3FU to expose the screw terminals for
the main line connection.
3.
Connect the three phase power to the top of
the disconnect and torque wires to the listed
torque shown on the panel above the
disconnect.
4.
Reinsert the fuses into the disconnect
switch.
5.
Close and secure the electrical panel’s door.
Leave the electrical disconnect switch in the
“Off” position.
DANGER
WARNING
WARNING
WARNING
Main Panel Ground Lug
Disconnect Switch
Screw Terminals