11.2
Function diagram of the system
AG-TRONIK receives information, required for calculation of actual liter per hectare from:
Flow sensor, which is built in section side of regulator;
Speed sensor, which is fitted on the sprayer wheel.
Flow sensor is a component part of regulator and is connected to electric connection cabinet
on the flow regulator. Speed sensor is connected to electric connection cabinet (4-pole
connector – fig. 62).
AG-TRONIK is supplied through three-pole connector on tractor electrical circuit with 12V
voltage.
Information on condition of central regulation valve and distribution valves is recived by AG-
TRONIK through connection cable from connection electrical cabinet, mounted beside
section valves. AG-TRONIK regulates work pressure through regulation valve on the
regulator, depending on flow capacity. It ensures that flow capacity equals desired flow
capacity (hectare consumption).
Figure 54: FUNCTIONAL DIAGRAM SYSTEM