![Agria Bison 5900 Series Translation Of The Original Operating Instructions Download Page 45](http://html1.mh-extra.com/html/agria/bison-5900-series/bison-5900-series_translation-of-the-original-operating-instructions_2869817045.webp)
4 Commissioning and Operation
Hydrostatic Implement Carrier
agria 5900 Bison
45
Starting the diesel engine, cable-pull starter version
1. Open the fuel cock (D/3)
2. Set speed regulating lever (B/9) to max.
3.
Safety lever (B/4) in stop position (released)
,
drive lever (B/10) in position "0"
4.
At the starter handle (D/6), slowly pull the
starter cable until you can feel resistance
(piston in compression position)
5.
Actuating the decompression valve: Pull the
rope (D/8)
6.
Start the engine from outside the hazard
zone:
Hold the starter rope at the starter handle (D/6)
and pull it out
vigorously
and
rapidly
to start the
engine. Guide the handle back after the engine
has started. Do not allow it to shoot back.
•
Decompression automatically moves back to
the initial position during the starting process
7. Hold the speed regulating lever at middle
position (medium throttle) and allow the en-
gine to warm up for a short time.
•
If the engine does not start, repeat the start-
ing process in the same sequence.