AGM RMSAL User Manual Download Page 24

24

AGM Global Vision

4   WARRANTY INFORMATION

4.1  WARRANTY INFORMATION

This product is guaranteed to be free from manufacturing defects in material and 

workmanship under normal use for a period of three (3) years from the date of 

purchase. In the event that a defect covered by the warranty below occurs during 

the applicable period stated above, AGM Global Vision, at its discretion, will either 

repair or replace the product; such action on the part of AGM Global Vision shall 

be the full extent of AGM Global Vision’s liability, and the Customer’s sole and 

exclusive reparation. This warranty does not cover a product if it has been (a) used 

in ways other than its normal and customary manner; (b) subjected to misuse; (c) 

subjected to alterations, modifications or repairs by the Customer or by any party 

other than AGM Global Vision without prior written consent of AGM Global Vision; 

(d) is the result of a special order or categorized as “close-out” merchandise or 

merchandise sold “as-is” by either AGM Global Vision or the AGM Global Vision 

dealer; or (e) merchandise that has been discontinued by the manufacturer and 

either parts or replacement units are not available due to reasons beyond the 

control of AGM Global Vision. AGM Global Vision shall not be responsible for 

any defects or damage that in AGM Global Vision’s view are a result from the 

mishandling, abuse, misuse, improper storage or improper operation of the device, 

including use in conjunction with equipment that is electrically or mechanically 

incompatible with, or of inferior quality to, the product, as well as failure to maintain 

the environmental conditions specified by the manufacturer. This warranty is 

extended only to the original purchaser. Any breach of this warranty shall be 

enforced unless the customer notifies AGM Global Vision at the address noted 

below within the applicable warranty period.
The customer understands and agrees that except for the foregoing warranty, 

no other warranties written or oral, statutory, expressed or implied, including any 

implied warranty of merchantability or fitness for a particular purpose, shall apply 
to the product. All such implied warranties are hereby and expressly disclaimed.

4.2 LIMITATION OF LIABILITY

AGM Global Vision will not be liable for any claims, actions, suits, proceedings, 

costs, expenses, damages, or liabilities arising out of the use of this product. 

Operation and use of the product are the sole responsibility of the Customer. AGM 

Global Vision’s sole undertaking is limited to providing the products and services 

outlined herein in accordance with the terms and conditions of this Agreement. 

The provision of products sold and services performed by AGM Global Vision to 

the Customer shall not be interpreted, construed, or regarded, either expressly or 

implied, as being for the benefit of or creating any obligation toward any third party 

of legal entity outside AGM Global Vision and the Customer; AGM Global Vision’s 

Summary of Contents for RMSAL

Page 1: ...USER MANUAL RMSAL RIFLE MOUNTED SQUAD AIMING LASER...

Page 2: ...on Regulations the International Economic Emergency Powers Act and various U S embargoes and sanctions AGM Global Vision products may not be exported re exported or transferred contrary to U S export...

Page 3: ...lation and Mounting 10 2 3 Controls and Indicators 13 2 4 Operating Procedures 18 SECTION 3 MAINTENANCE INSTRUCTIONS 21 3 1 RMSAL Preventive Maintenance 21 3 2 User Level Troubleshooting 22 SECTION 4...

Page 4: ...lasers at mirrors or highly reflective surfaces Do not point direct or shine the lasers into the eyes of other individuals CAUTION Verify that the device is OFF before installing a battery Do not dism...

Page 5: ...iscrete intervals In addition the aiming lasers can be operated via user selectable switch in either a constant wave or 4 Hz pulsed mode The lasers can be activated either by remote switch assembly or...

Page 6: ...LASER ON Indicator LED 4 Battery Cap and Battery Compartment One each 123A 3 0 VDC Lithium Battery 5 Ballistic Adjuster Elevation CW MPI up CCW MPI down 6 Ballistic Adjuster Tool threaded into backpl...

Page 7: ...ER 21 Near IR Aimer POWER DIMMER 22 RMSAL Power Activation Button non remote NOTES The RMSAL is supplied with two 2 remote cable switches NOT SHOWN The black remote cable switch with BLACK button give...

Page 8: ...number used to identify items in Figure 1 2 TABLE 1 2 STANDARD COMPONENTS ITEM DESCRIPTION 1 RMSAL Unit Assembly 2 CR123A Lithium Battery 3 Operator Manual 4 Soft Carrying Case 5 Remote Switch Assembl...

Page 9: ...ht vision compatible mode Adjustable output power User selectable constant wave or pulsed modes of aiming lasers Two tactical remote switches including SAFETY remote switch Aiming lasers are co bore s...

Page 10: ...gh magnified optics such as binoculars or telescopes Do not point the lasers at mirrors or highly reflective surfaces Do not point direct or shine the lasers into the eyes of other individuals CAUTION...

Page 11: ...Stop turning the cam CCW when it reaches the end of it travel and you meet resistance Wrap the fixed jaw over the weapon rail center the recoil stop in a recoil groove and then tighten the translating...

Page 12: ...button will remain in eye safe operational mode until such time as the BLACK Tactical remote switch is installed which then automatically resets the power circuits for full output power range access...

Page 13: ...tch assembly is activated or the integral FIRE button located on the top of the RMSAL is pushed Note that when the RMSAL is positioned on the weapon rail at the 9 o clock position the stabilizing hand...

Page 14: ...M IR ILLUM Both Near IR Aiming Laser and near IR Illuminator emit together The dual operation of the near IR aiming laser and Illuminator permit the target to be flushed out while the aiming laser dir...

Page 15: ...on is labeled with the following icon _____ _____ _____ Note that the pulse selection button does NOT cause the near IR illuminator to pulse This feature is particularly useful when working in two man...

Page 16: ...ety monitors There are two 2 light emitting diodes LED on the rear bulkhead of the RMSAL The first is a bi color LED labeled BATT that has two functions The first is to warn the operator that the batt...

Page 17: ...mode 2 3 7 BALLISTIC ADJUSTERS Ballistic adjusters on the RMSAL employ a novel departure from the standard contemporary designs in creating a weapon bore sighted laser First the ballistic adjuster bo...

Page 18: ...quipment in order to boresight beware of reflections from optical surfaces To boresight the RMSAL 1 Locate a target at the fire adjustment range 25 m 2 Take aim at the center of the target using the w...

Page 19: ...y orientation Install battery cap 2 If you are operating the device using limited laser output to 600 W Class I for eye safe applications such as initial operator or force on force exercises use the B...

Page 20: ...another operation mode turn the switch to the desired position and reactivate the laser s by pushing FIRE button 2 4 3 CONSTANT WAVE PULSE WAVE APPLICATIONS To change the pulse mode of the aiming lase...

Page 21: ...bserved to be dried out then the O ring should be replaced If the battery cap is bent or scratched scarred in the O ring seat area then it should be replaced Periodically lubricate all O rings with fl...

Page 22: ...authority within the unit or transfer to a more sophisticated maintenance and repair level TABLE 4 1 RMSAL USER LEVEL DIAGNOSES AND TROUBLESHOOTING ITEM MALFUNCTION TEST INSPECTION CORRECTIVE ACTION 1...

Page 23: ...urn system back on and check power range adjustments 4 Aiming beams do not move a Check adjusters If dirty clean as needed If damaged return to Unit Level Maintenance 5 Remote Switch Inoperable but FI...

Page 24: ...oper storage or improper operation of the device including use in conjunction with equipment that is electrically or mechanically incompatible with or of inferior quality to the product as well as fai...

Page 25: ...oration s service center at the address listed above All merchandise must be fully insured with the correct postage AGM Global Vision will not be responsible for improper postage or merchandise that b...

Page 26: ...mW Operating Distance 25 m in direct sunlight Visible Beam Divergence 0 5 mRad Visible Wavelength Red 605 nm 665 nm Green 500 nm 530 nm IR Illuminator Specification IR Class IIIb near IR IR Output 50...

Page 27: ...bel Mode Selection Knob 7 Lens Cap Near IR Illuminator 8 Lens Cap Visible near IR Aiming Laser Port 9 Dual Lanyard Assembly illuminator aiming laser port 10 Remote Switch Assembly Tactical Full Access...

Page 28: ...ain Street PO Box 962 Springerville AZ 85938 USA Tel 1 928 333 4300 Fax 1 480 393 4882 info agmglobalvision com www agmglobalvision com EUROPEAN OFFICE Andrey Lyapchev 7 Sofia P C 1756 Bulgaria Tel 44...

Reviews: