20
AGM Global Vision
output power range of the IR lasers consists of 256 increments that can be
individually tapped. By depressing and holding either the power up or power
down button, the power will increase or decrease in increments of eight (8)
settings at a time allowing the operator to experience the full range from
lowest to highest power setting (or vice-versa) within five (5) seconds.
WARNING:
DO NOT leave the RMSAL activated when it’s not in use.
WARNING:
The IR light from the equipment’s IR laser(s) is invisible to the naked eye.
However, the light can be detected by all night vision devices. To reduce the
risk of detection, avoid prolonged activation of the IR laser(s).
NOTE:
To switch the activated equipment to another operation mode, turn the switch
to the desired position and reactivate the laser(s) by pushing FIRE button.
2.4.3 CONSTANT WAVE / PULSE WAVE APPLICATIONS
To change the pulse mode of the aiming laser:
1. When in the constant wave mode, push the aft button labeled (- - -) to change
the aiming laser to 4Hz pulsing.
2. Press the aft button labeled (- - -) again to return to constant wave mode.
NOTE:
Proper laser protocol is to locate a target with your NVDs and then activate the
laser for no more than two seconds at a time in order to prosecute the target.
2.4.4 RMSAL SHUT-DOWN
To shut down the RMSAL:
1. Turn the rotary switch to OFF.
2. Replace the cap(s) on the laser output aperture(s).
3. Remove the remote switch by pulling on the plug (not the cable).
4. Remove the equipment from the weapon rail.
5. Remove the battery.
CAUTION:
Do not store the equipment with the battery still installed.
6. Store the RMSAL and all accessories in the case.