22
AGM Global Vision
3.2 USER LEVEL TROUBLESHOOTING
The primary purpose of troubleshooting is to identify and diagnose the most
frequent field level equipment malfunctions, investigate probable causes, and
apply corrective actions where possible and required.
The table below lists the common malfunctions that an operator may
experience during the operation or maintenance of the RMSAL and its standard
kit accessories. Maximum success in diagnosing a problem and applying
a corrective action is derived from performing the tests, inspections, and
corrective actions in the order listed.
This manual cannot list all of the possible malfunctions that may occur, nor all
tests, inspections, and corrective actions that may be available at a higher level
of maintenance and logistics support. If a malfunction is not listed or is not
corrected by the corrective actions listed below, it may require escalation to a
higher authority within the unit or transfer to a more sophisticated maintenance
and repair level.
TABLE 4-1. RMSAL USER LEVEL DIAGNOSES AND TROUBLESHOOTING
ITEM MALFUNCTION
TEST/INSPECTION
CORRECTIVE ACTION
1
Aiming
and/or
Illumination
beams fail
to come on
when a lasing
mode is
selected.
a.) Check to see if lens caps
are removed.
b.) Check to see if laser
beam windows are obscured
with mud, dirt or foreign
debris.
c.) Check battery Installation.
d.) Check mode selection
settings.
e.) Check remote switches.
f.) Internal failure.
Remove lens caps.
Clean laser windows.
Check battery orientation.
Change to fresh batteries.
Verify settings and reset.
Verify if unit works on
“FIRE” button mode.
Replace damaged remote.
Return to Unit Level
Maintenance.
2
RMSAL
does not
operate when
mounted on a
weapon.
a.) Remove RMSAL from
weapon and perform
inspections and diagnoses in
section 1 above.
b.) Check rail grabber and
weapon rails for damage.
c.) Check remote cables.
d.) Review installation
procedures and re-install on
weapon.
Return rail or RMSAL to
Unit Maintenance for repair.
Verify if unit works on
“FIRE” button mode.
Replace damaged remote.
Re-install.