background image

Notices

© Agilent Technologies, Inc. 2019

No part of this manual may be reproduced 
in any form or by any means (including 
electronic storage and retrieval or transla-
tion into a foreign language) without prior 
agreement and written consent from 

Agilent Technologies, Inc. as governed by 
United States and international copyright 
laws.

Manual Part Number

103346-400

Kit Part Number

103346-100

Edition

Second edition, May 2019

Revision B0

Printed in USA

Agilent Technologies, Inc.

2850 Centerville Road 

Wilmington, DE 19808-1610 USA

Warranty

The material contained in this docu-
ment is provided “as is,” and is sub-
ject to being changed, without notice, 
in future editions. Further, to the max-
imum extent permitted by applicable 
law, Agilent disclaims all warranties, 
either express or implied, with regard 
to this manual and any information 
contained herein, including but not 
limited to the implied warranties of 
merchantability and fitness for a par-
ticular purpose. Agilent shall not be 
liable for errors or for incidental or 
consequential damages in connection 
with the furnishing, use, or perfor-
mance of this document or of any 
information contained herein. Should 
Agilent and the user have a separate 
written agreement with warranty 
terms covering the material in this 
document that conflict with these 
terms, the warranty terms in the sep-
arate agreement shall control.

Technology Licenses 

The hardware and/or software described in 
this document are furnished under a 
license and may be used or copied only in 
accordance with the terms of such license.

Restricted Rights Legend

If software is for use in the performance of 
a U.S. Government prime contract or sub-
contract, Software is delivered and 
licensed as “Commercial computer soft-
ware” as defined in DFAR 252.227-7014 
(June 1995), or as a “commercial item” as 
defined in FAR 2.101(a) or as “Restricted 
computer software” as defined in FAR 
52.227-19 (June 1987) or any equivalent 
agency regulation or contract clause. Use, 
duplication or disclosure of Software is 
subject to Agilent Technologies’ standard 
commercial license terms, and non-DOD 
Departments and Agencies of the U.S. 

Government will receive no greater than 
Restricted Rights as defined in FAR 
52.227-19(c)(1-2) (June 1987). U.S. Govern-
ment users will receive no greater than 
Limited Rights as defined in FAR 52.227-14 

(June 1987) or DFAR 252.227-7015 (b)(2) 
(November 1995), as applicable in any 
technical data.

Safety Notices

C A U T I O N

CAUTION

 notice denotes a 

hazard. It calls attention to an oper-
ating procedure, practice, or the 
like that, if not correctly performed 
or adhered to, could result in 

damage to the product or loss of 
important data. Do not proceed 
beyond a 

CAUTION

 notice until the 

indicated conditions are fully 
understood and met. 

W A R N I N G

A WARNING notice denotes a 
hazard. It calls attention to an 
operating procedure, practice, or 
the like that, if not correctly per-
formed or adhered to, could result 
in personal injury or death. Do not 
proceed beyond a WARNING 
notice until the indicated condi-
tions are fully understood and met.

Summary of Contents for Seahorse XFp

Page 1: ...Agilent Technologies Agilent Seahorse XFp Glycolytic Rate Assay Kit User Guide Kit 103346 100...

Page 2: ...ibed in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a...

Page 3: ...ckground 5 Glossary 9 Kit Information Kit Contents 11 Kit Shipping and Storage 11 Additional Required Items 12 Assay Workflow Day Prior to Assay 14 Day of Assay 14 Running the Assay 18 Analysis Using...

Page 4: ...4 Agilent Seahorse XFp Glycolytic Rate Assay Kit User Guide...

Page 5: ...reliable method for measuring glycolysis in cells Together with a Seahorse XFp Analyzer the Seahorse XFp Glycolytic Rate Assay provides accurate measurements of glycolytic rates for basal conditions...

Page 6: ...PER of the cells defined below Glucose in cells is converted to pyruvate and then converted to lactate in the cytoplasm or to CO2 and water in the mitochondria The conversion of glucose to lactate res...

Page 7: ...xtruded into the extracellular medium during glycolysis This assay allows for real time measurements of changes in glycolysis rates that may go undetected in long term lactate accumulation assays The...

Page 8: ...ular media which is detected by the XFp Analyzer as ECAR Additionally mitochondrial TCA activity produces CO2 which hydrates and acidifies the media By inhibiting respiration OCR during the assay with...

Page 9: ...extracellular lactate production rate Compensatory glycolysis The rate of glycolysis in cells following the addition of mitochondrial inhibitors effectively inhibiting oxidative phosphorylation and d...

Page 10: ...10 Agilent Seahorse XFp Glycolytic Rate Assay Kit User Guide Introduction...

Page 11: ...mperature The product is stable for one year from the date of manufacture The actual expiration date is printed on the label of the assay kit box Depending on the shipping date the actual shelf life o...

Page 12: ...cartidges miniplates and calibrant Agilent Technologies 103022 100 XF DMEM medium pH 7 4 or XF RPMI medium pH 7 4 XF DMEM or RPMI media can also be purchased together with the supplements listed in th...

Page 13: ...t User Guide Agilent Technologies 3 Assay Workflow Day Prior to Assay 14 Day of Assay 14 Running the Assay 18 Analysis Using the Agilent Seahorse Glycolytic Rate Assay Report Generator 19 Figure 3 Agi...

Page 14: ...No 103575 100 and 103576 100 These media contain the appropriate amount of HEPES and NO additional HEPES is needed It is recommended to start with 1 mM pyruvate 2 mM glutamine and 10 mM glucose Howeve...

Page 15: ...say for details Remove the cell culture growth medium in the cell culture miniplate Wash once with warmed assay medium using a multichannel pipette and incubate with assay medium at 37 C in a non CO2...

Page 16: ...s on the bottom of the tube Vortex 1 minute to ensure that compounds go into solution Dilute compounds Table 3 describes how to prepare compounds dilutions to load the cartridge Please note that if di...

Page 17: ...rior to the Glycolytic Rate Assay compounds use port A for the desired compound and then load ports as follows Port A experimental compound acute injection or media control Port B Rot AA Port C 2 DG T...

Page 18: ...rted then click Import 7 All imported Assay Templates will now be available for selection from the Local tab when starting an XFp assay Run the Seahorse XF Glycolytic Rate Assay 1 Click Start 2 Select...

Page 19: ...save your assay file asyr 2 In your Desktop version of Wave 2 3 or higher open the file from your USB Flash Drive 3 From Wave export the data from the completed run as an xls file 4 Load the data fil...

Page 20: ...20 Agilent Seahorse XFp Glycolytic Rate Assay Kit User Guide Assay Workflow...

Page 21: ...nd using the Buffer Factor BF and CO2 contribution factor CCF the mitochondrial PER is calculated and subtracted to generate the glycoPER The Seahorse XF Glycolytic Rate Assay reports the percentage o...

Page 22: ...chondrial sources of acidification as well as reporting the data in standard units pmol min These features make the Seahorse XF Glycolytic Rate Assay highly comparable to extracellular lactate product...

Page 23: ......

Page 24: ...Agilent Technologies For research use only Not for use in diagnostic procedures Agilent Technologies Inc Printed in USA May 2019 Revision B0 103346 400 103346 400...

Reviews: