Specifications and Characteristics
Specifications and Characteristics
Specifications
Supplemental Characteristics (typical)
Common Characteristics (typical)
Unless otherwise noted, specifications are warranted over the ambient temperature range of 0°C to 45°C after a 30-
minute warm-up period. Specifications apply from >2% to 100% of rated voltage and from >1% to 100% of rated cur-
rent, measured at the output terminals with local sensing (sense terminals not connected).
Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by
type testing. All supplemental characteristics are typical unless otherwise noted.
Specifications and characteristics are subject to change without notice.
Specifications
Specification 5 kW
N8920A
N8940A
N8921A
N8941A
N8923A
N8943A
N8924A
N8944A
DC Ratings
Voltage:
Current:
Power:
0 - 80 V
0 - 170 A
5 kW
0 - 200 V
0 - 70 A
5 kW
0 - 500 V
0 - 30 A
5 kW
0 - 750 V
0 - 20 A
5 kW
Output ripple & noise1
CV rms:
CV peak-to-peak:
16 mV
200 mV
40 mV
300 mV
70 mV
350 mV
2
0
0 mV
800 mV
Load regulation
Voltage:
Current:
40 mV
255 mA
100 mV
105 mA
250 mV
45 mA
375 mV
30 mA
Voltage programming &
measurement accuracy2
≤ 80 mV
≤ 200 mV
≤ 500 mV
≤ 750 mV
Current programming &
measurement accuracy2
≤ 340 mA
≤ 140 mA
≤ 60 mA
≤ 40 mA
Transient response3
Recovery Time:
Settling band:
1.5 ms
0.8 V
1.5 ms
2 V
1.5 ms
5 V
1.5 ms
7.5 V
Agilent N8900 Series Operating and Service Guide
9
Summary of Contents for N8900 series
Page 1: ...Agilent N8900 Series Autoranging System DC Power Supply Operating and Service Guide...
Page 36: ...Multiple Unit Connections Agilent N8900 Series Operating and Service Guide 35...
Page 104: ...Status Tutorial Status Diagram Agilent N8900 Series Operating and Service Guide 103...
Page 119: ......