Agilent E1439 Programmer's Reference
Functions listed by functional group
Initializing and closing
age1439_init
(on page 132)
−
initializes the I/O driver for a module
age1439_close
(on page 86)
−
closes the module's software connection
Analog setup
age1439_input_setup
(on page 141)
−
sets all the analog input parameters
age1439_input_alias_filter
(on page 141)
−
include/bypass the built-in analog anti-alias filter
age1439_input_alias_filter_get
(on page 141)
−
gets the anti-alias filter state
age1439_input_autozero
(on page 141)
−
nulls out the input dc offset in baseband mode
age1439_input_coupling
(on page 141)
−
selects ac or dc input coupling
age1439_input_coupling_get
(on page 141)
−
get the input coupling type
age1439_input_offset
(on page 135)
−
sets the dc offset settings for the current range
age1439_input_offset_get
(on page 135)
−
gets the dc offset settings
age1439_input_offset_save
(on page 136)
−
saves the dc offset settings in NVRAM
age1439_input_range
(on page 141)
−
sets the full scale input range
age1439_input_range_auto
(on page 137)
−
performs auto-ranging
age1439_input_range_convert
(on page 138)
−
converts input range to volts
age1439_input_range_get
(on page 141)
−
gets the input range
age1439_input_signal_path
(on page 141)
−
selects baseband or IF signal path
age1439_input_signal_path_get
(on page 141)
−
gets the signal path state
age1439_input_signal
(on page 141)
−
connect/disconnect the input signal to the input ampli-
fier
age1439_input_signal_get
(on page 141)
−
gets the input buffer amplifier state
age1439_state_save
(on page 175)
−
saves the current module state
age1439_state_recall
(on page 174)
−
recalls a previous module state
Data format
age1439_data_setup
(on page 90)
−
sets all format and data output flow parameters
age1439_data_blocksize
(on page 90)
−
determines the size of the output data block
age1439_data_blocksize_get
(on page 90)
−
gets the output data block size
age1439_data_delay
(on page 90)
−
determines FIFO delay in continuous mode
age1439_data_delay_get
(on page 90)
−
gets FIFO delay
age1439_data_memsize_get
(on page 88)
−
returns module's memory size
age1439_data_mode
(on page 90)
−
selects block mode or continuous mode
age1439_data_mode_get
(on page 90)
−
gets the data mode
age1439_data_port
(on page 90)
−
selects VME bus, local bus or fiber interface for output
transmission
age1439_data_port_get
(on page 90)
−
gets the output port designation
age1439_data_resolution
(on page 90)
−
selects 12 or 24 bits data resolution
age1439_data_resolution_get
(on page 90)
−
gets the data resolution
age1439_data_scale_get
(on page 89)
−
gets the data scale factor used to convert raw data to
volts
age1439_data_type
(on page 90)
−
selects real or complex output data
age1439_data_type_get
(on page 90)
−
gets output data type
age1439_data_spectral_order
−
specifies the spectral order of the output data.
age1439_data_spectral_order_get
−
gets the spectral order of the output data.
age1439_data_xfersize
(on page 96)
−
allows a specified amount of data to be read before an
entire block has been acquired.
age1439_data_xfersize_get
(on page 96)
−
gets the data transfer size
Summary of Contents for E1439
Page 6: ...6...
Page 10: ...10 Contents...
Page 11: ...1 1 Installing the Agilent E1439...
Page 18: ...8 Installing the Agilent E1439 To transport the module...
Page 19: ...2 2 Getting Started with the Agilent E1439...
Page 28: ...18 Getting Started with the Agilent E1439 To use the example programs...
Page 29: ...3 3 Using the Agilent E1439...
Page 63: ...4 4 Agilent E1439 Programmer s Reference...
Page 217: ...5 5 Module Description...
Page 228: ...218 Module Description Block diagram and description...
Page 229: ...6 6 Replacing Assemblies...
Page 234: ...224 Replacing Assemblies Replaceable parts To remove the top cover...
Page 235: ...225 Replacing Assemblies Replaceable parts To remove the M1 M2 assemblies...
Page 236: ...226 Replacing Assemblies Replaceable parts...
Page 238: ...228...
Page 244: ...Index 234...