54
P1512137 R3
9. Check all operating, lifting, and transport components. Replace damaged or worn parts before using the
conveyor.
Æ
10.
PTO Models:
Check the PTO shield & replace if damaged.
Æ
11.
If equipped with truss cables:
Inspect the truss cables for proper tension and possible damage such as
fraying, kinking, or unwinding.
7.4. Lubricate the Equipment
Your equipment can operate at top efficiency only if clean fluids and lubricants are used. Use clean containers
to handle all fluids and lubricants. Store them in an area protected from dust, moisture, and other
contaminants.
1. Wipe the grease fittings with a clean cloth before greasing to avoid injecting dirt and grit.
2. Use a hand-held grease gun for all greasing.
3. If fittings will not take grease, remove and clean thoroughly.
4. Replace fittings if they are broken or will not accept grease.
Use SAE multi-purpose high-temperature grease with extreme pressure (EP) performance. SAE multi-purpose
lithium-based grease is also acceptable.
7.4.1 PTO Driveline
Figure 20.
Typical PTO Driveline Grease Points
Figure 21.
Typical PTO Driveline Grease Points
7.5. Check the Gearbox Oil
1. Remove fill/vent plug to check gearbox oil level. Insert an improvised dipstick (rolled paper or plastic tie)
into the oil filler hole to determine the oil level.
S-DRIVE STANDARD CONVEYOR – PORTABLE GRAIN BELT CONVEYOR