A
PPENDIX
B
38
AGCO RoGator RG900/1100/1300 Hawkeye™ Installation Manual
7. Identify and disconnect the green/yellow twisted wires that lead to a 4-pin Deutsch connector in the electrical
box.
8. Connect the 4-pin Deutsch receptacle coming from the bulkhead connector to the mating 4-pin plug on the
ISOBUS adapter tee (P/N 115-0172-325 Rev B) where the adapter and terminator were removed.
NOTE:
If the ISOBUS Tee Cable (P/N 115-0172-325 Rev B) was previously installed, skip step 9 through
9. Remove the first connector from the front of the ISOBUS bar located in the bottom of the electrical box along
the edge closest to the rear of the machine.
FIGURE 2. First ISOBUS Bar Connector.
10. Locate and disconnect the square Raven passive terminator on the cable harness near the Sidekick Pro
Injection Pumps.
11. Locate the 4-Pin adapter cable and ISOBUS terminator removed from the ISOBUS Tee Cable (P/N 115-0172-325
Rev B) in a previous step.
12. Install the adapter and ISOBUS terminator onto the connection that the Raven Passive Terminator was removed
from.
13. Plug the mating connector of the ISOBUS adapter tee (P/N 115-0172-325 Rev B) into the open first port of the
ISOBUS bar.
14. Plug the remaining connector of the ISOBUS adapter tee into the open port of the ISOBUS bar.
15. If the Hawkeye Retrofit Cable (P/N 115-0172-325 Rev B) was not previously connected to the ISOBUS Tee Cable,
connect the mating connector to the remaining open connector of the ISOBUS Tee Cable.
Disconnect
Summary of Contents for RoGator 1100
Page 16: ...CHAPTER 3 12 AGCO RoGator RG900 1100 1300 Hawkeye Installation Manual...
Page 32: ...CHAPTER 5 28 AGCO RoGator RG900 1100 1300 Hawkeye Installation Manual...
Page 37: ...P N 016 0171 588 Rev D 33 CHASSIS CABLE INSTALLATION FIGURE 7 System Diagram Page 1...
Page 44: ...APPENDIX B 40 AGCO RoGator RG900 1100 1300 Hawkeye Installation Manual...