![AGCO RoGator 1100 Installation Manual Download Page 40](http://html1.mh-extra.com/html/agco/rogator-1100/rogator-1100_installation-manual_2866436040.webp)
A
PPENDIX
A
36
AGCO RoGator RG900/1100/1300 Hawkeye™ Installation Manual
FIGURE 2. Upper Panel Right of the Operator Seat
4. Disconnect the ISO terminator from the 3-pin connector.
5. Plug in the ISOBUS adapter cable to the connectors to allow the ROS device to interface with the machine
ISOBUS and the Raven Hawkeye nozzle control system.
6. Plug the ISO terminator plug on to the second connector on the cable installed in Figure 5 on page 36.
7. Route the adapter cable to the back of the ROS device and connect to the receptacle labeled “5.”
8. To prevent issues with the Hawkeye Icon showing up on the C1000, perform the steps in AGCO Service Bulletin
Number 16-0104. This bulleting provides the steps to set the ISOBUS Terminal Generation to UT 2, turn the
ISOBUS Terminal Functions On, and assign the terminal number.
Summary of Contents for RoGator 1100
Page 16: ...CHAPTER 3 12 AGCO RoGator RG900 1100 1300 Hawkeye Installation Manual...
Page 32: ...CHAPTER 5 28 AGCO RoGator RG900 1100 1300 Hawkeye Installation Manual...
Page 37: ...P N 016 0171 588 Rev D 33 CHASSIS CABLE INSTALLATION FIGURE 7 System Diagram Page 1...