Ag Leader Technology
Cotton Picker Installation
CaseIH 2055
November 2002
2006200-1
9-15
3. Start routing the sensor distribution cable at the right side of the picker. Ensure
to get the correct end of the cable. It has an extended cable with the AMP
CP14 pin, which will run to the main distribution cable on the backside of the
cab.
4. Connect the AMP 14 pin connector into the back of each of the detectors
starting at the right side so they are in order on the monitor. Row 1 is on the
left side of the machine.
5. Tie the sensor distribution cable to the monkey bars directly below the sensors
with as many ties as needed.
6. Connect all emitters and detectors pairs together using the 4-pin connection as
seen in Figure 14.
Figure 14. Connect Emitter and Detector.
7. Route the single sensor cable from the far right side to the back of the cab
where the main distribution cable is located.
8. Connect the 14-pin connector of the sensor cable to the distribution cable.
Connector
Detector
Emitter