Cotton Picker Installation
Ag Leader Technology
CaseIH 2055
November 2002
2006200-1
9-14
Installing Flow
Sensors and
Sensor Cable
Parts required for this procedure:
•
Four, 5 Position Emitters
•
Four, 5 Position Detectors
•
Sensor Distribution Cable
•
Installation Kit
Description
Emitter
– sensor block that is thicker and has a right angle connector coming out of
the top cover with a two foot long cable.
Detector
– sensor block that is thinner and has an AMP 14-pin connector mounted
on the back cover.
Step-by-Step
Procedure
1. Install the emitters on the front side of the hood adapters. Ensure the captive
nuts are tight so no vibration can occur to the sensor. See Figure 13.
2. The detectors should be installed on the backside of the hoods or side towards
the basket.
Figure 13. Emitters installed on hood.