Cotton Picker Installation
Ag Leader Technology
CaseIH 2055
November 2002
2006200-1
9-8
Installing
Switched Power,
Fan Speed,
Ground Speed
Cable
Parts required for this procedure:
•
Switched power, Fan Speed, Ground Speed (FGP) cable (identified by a 9-pin
tee connector on one end and a 4-pin shroud on the other end)
Step-by-Step
Procedure
NOTE: When facing the exposed access panel on the exterior of the cab,
the digital tachometer is located towards the top on the right hand side.
1. Disconnect the existing 9-pin connector plugged into the digital tachometer.
Figure 8. 9-Pin connector attached.
2. Tee the 9-pin end of the FGP cable into the existing wiring harness of the
digital tachometer.
NOTE: Attach the 4-pin shroud end of the FGP cable into the short 4-pin
tower connector towards the 24-pin end of the cab cable.
Digital
Tachometer