31
Cont. of Table B.6
1
2
3
4
5
6
Volume for any flow direction
V
x
Signal upon batching completion
pul. batcher
x
Reversing flow direction
sign
x
No ultrasonic signal
no signal
x
Flowrate exceeds the high
setpoint
Q
Qup
x
Flowrate is less than the low
setpoint
Q
Qlw
x
Flowrate exceeds the upper limit
Q
Qut
Flowrate is less than the lower
limit
Q
Qlt
Flowrate exceeds the maximum
flowrate value
Q
Qmax
Active level signal is generated
on the output when batching is
completed
batcher
x
Table B.7. Menu "STATUS LOGS" (Fig.A.8)
Representation
of the parameter
being displayed
Parameter Name,
measurement units
Value range, rep-
resentation form
Value
after
initialization
Notes
ERROR LOGS
Ter
Event duration
XX:XX:XX
(hh:mm:ss)
0
-
Data of event start or end
XX.XX.XX
(dd.mm.yy)
-
-
Time of event start or end
XX:XX:XX
(hh:mm:ss)
-
Curr. record
Sequential number of the rec-
ord to be searched for after
entering the new value
1-1000
*
does not change
CURR. STATUS chan.
X
ER
Measuring channel status word
15 character plac-
es**
(see Table D.1)
-
DS
Status word of quantized out-
puts
13 character plac-
es**
(see Table D.3)
-
FL
Status word of failures
4 character plac-
es**
(see Table D.4)
-
* - Maximum number of records depends on the type of log
** - Character "
" means that event occurred, character "-" that it didn't;
positions in status words are enumerated
from right to left
Summary of Contents for UF-5 Series
Page 17: ...17 Fig A 1 Main menu ...
Page 18: ...18 Fig A 2 Menu FLOW DATA ...
Page 20: ...20 Fig A 4 Menu WALL MATER and COAT MATER Fig A 5 Menu Process depend data ...
Page 22: ...22 Fig A 7 Menu PERIPHERY SETTINGS ...
Page 23: ...23 Fig A 8 Menu STATUS LOGS ...
Page 24: ...24 Fig A 9 Menu DATA LOGS ...