LAMINATION MODULE
(DLF-220L AND DLF-350L MODELS)
MATRIX REMOVER
AND SLITTER MODULE
MEDIA PATH
ULTRASONIC SENSOR CALIBRATION
WARNING:
Before proceeding with the ultrasonic sensor
calibration, turn “OFF” the module that needs to be calibrated
(laminating or matrix removing).
For DLF-220L/DLF-350L: turn “ON” the unwinder when
you procede to the sensor calibration.
1.
Raise the tension arm to the fullest (spring has to extend completely).
2.
Take a paper clip and insert it into the little hole located next to the OFF-ON
switch and push it down for 5 seconds. The yellow led will light up.
3.
Release the tension arm. The yellow led will stay on.
4.
Push again the paper clip down into the hole for 5 seconds. The led will light off.
Ultrasonic sensor calibration complete.
24