AFG Arbonia WFS Instructions For Use And Installation Instructions Download Page 9

9

State

Meaning

Lights red

Heating phase

Lights yellow

Setpoint temperature has 
been reached, heating ele-
ment is switched off

Blinks red

Radio communication 
impaired, check thermostat 
WFS

Setup of the operating mode

In  the  as-delivered  condition,  the  thermostat 

is programmed for regulating the room tem-
perature.  If  a  regulation  independent  of  the 
room  temperature  of  the  radiator  tempera-

ture is desired (e.g. because the room tempe

-

rature is regulated via panel heating), execute 
the following steps according to Fig. F1-F3:

 

 

Remove the housing cover (5) carefully.

 

Set the rotary switch (9) to the "1" position.

 

LED  display  (4)  displays  the  conversion 
by blinking yellow.

 

Display of the operating mode goes out.

 

Towel warming mode is active.

 

Re-attach the housing cover (5).

If  regulation  of  room  temperature  is  desired 

instead  of  towel  warming,  repeat  the  above 
mentioned steps. For this, set the rotary switch 
(9) to the "0" position. The LED display (4) dis

-

plays the conversion by blinking red.
Position of the rotary switch (9)

• 

"0" = Room temperature regulation mode

• 

"1" = Towel warming mode

Display of the set mode

 

Keep the boost button (3) pressed for ap

-

proximately 10 seconds.

 

LED display (4) blinks red 

 

 

–> room temperature regulation mode

 

LED display (4) blinks yellow 

 

 

–> towel warming mode

 

Display of the operating mode goes out.

 

The thermostat is ready to operate.

IT – Istruzioni per l'uso

Uso consentito

Il  termostato  serve  per  la  regolazione  della 

temperatura  ambiente  o  della  temperatura 
del radiatore, ad esempio per il riscaldamento 
degli asciugamani, in unione ad una barra ter-

mina elettrica in radiatori fissi.

Ogni altro uso non è considerato conforme alle 
disposizioni ed è quindi non ammesso.

 

Indicazioni di sicurezza

 

Non  utilizzare  l'apparecchio  prima 
dell'installazione definitiva e conforme alle 

norme.

 

ATTENZIONE 

Pericolo di ustioni! Alcune parti 

del radiatore possono diventare 

molto calde.

 

Sorvegliare  i  bambini  affinché 

non  giochino  con  l'apparec-

chio. 

 

Osservare  le  istruzioni  vigenti 

della barra termica e del radia-

tore. 

Questo  apparecchio  può  essere 
utilizzato  da  persone  con  limitate 

capacità  fisiche,  sensoriali  o  men

-

tali  o  con  scarsa  esperienza  o  co-

noscenza e da bambini dagli 8 anni 

in su, se non lasciati soli o se istruiti 

sull’utilizzo sicuro dell’apparecchio 

e  in  grado  di  capire  i  pericoli  che 
possono sorgere.

I bambini di età inferiore ai 3 anni 
devono  essere  mantenuti  lontani 

dall'apparecchio,  a  meno  che  non 

vengano costantemente controllati.
I  bambini  dai  3  agli  8  anni  pos

-

sono  solo  accendere  e  spegnere 
l'apparecchio  nel  rispetto  delle 
condizioni  sopra  indicate  e  con 

Summary of Contents for Arbonia WFS

Page 1: ...r l l ment chauf fant lectrique 2013 08 6912022 AKP Arbonia AG Amriswilerstrasse 50 CH 9320 Arbon T 41 71 447 47 47 F 41 71 447 48 47 www arbonia ch AKP AFG Arbonia Forster Riesa GmbH Heinrich Sch nbe...

Page 2: ...sichtigt oder bez g lich des sicheren Gebrauchs des Ge r tes unterwiesen wurden und die daraus resultierenden Gefahren verstehen Kinder j nger als 3 Jahre sind vom Ger t fernzuhalten es sei denn sie w...

Page 3: ...ber einen Temperatursensor im Empf nger weiter hin aktiv DE Montageanleitung Das Ger t darf nur von einer Elektrofachkraft in Deutschland gem BGV A3 angeschlossen werden Sicherheitshinweise Vor der Mo...

Page 4: ...fiehlt es sich eine Schalterdose mit einer Einbautiefe 40 mm und einem Durchmesser von 68 mm zu verwenden Nach der Montage die Anleitung dem End verbraucher berlassen WARNUNG Lebensgefahr durch Stroms...

Page 5: ...n Einstellung der Betriebsart Der Thermostat ist im Auslieferungszustand auf die Regulierung der Raumtemperatur programmiert Wird eine raumtemperaturun abh ngige Regulierung der Temperatur des Heizk r...

Page 6: ...may also not carry out maintenance by the user Cleaning Disconnect the device from the power sup ply before cleaning or maintenance Use only mild non abrasive cleansing agents Complaint Contact your l...

Page 7: ...due to safety reasons However the an tifreeze function remains active in the receiver via a temperature sensor EN Installation instructions The device may only be connected by an elec trical specialis...

Page 8: ...th radio receiver Installation Preparatory activities Ensure that a outlet socket 230 V fuse B16 A is there within the reach of the cable of the heating element To install a radio receiver it is advis...

Page 9: ...temperature regulation mode LED display 4 blinks yellow towel warming mode Display of the operating mode goes out The thermostat is ready to operate IT Istruzioni per l uso Uso consentito Il termosta...

Page 10: ...2 4 1 Regolatore di temperatura temperatura ambiente circa 7 27 C temperatura del radiatore circa 40 65 C 2 Scala del regolatore di temperatura 3 Tasto Boost 4 Visualizzazione LED modalit di esercizio...

Page 11: ...T Istruzioni di montaggio L apparecchio pu essere installato solo da un elettricista specializzato Elettricista qualifica to colui che per formazione conoscenza ed esperienza tecnica nonch conoscenza...

Page 12: ...termica DIN 55900 Rivestimenti per radiatori per ambienti Termostato WFS Presa dell aria a muro IPX4 con radiori cevitore Montaggio Operazioni di preparazione Assicurarsi che alla portata del cavo del...

Page 13: ...posto del tipo di esercizio riscaldamento asciugamano si desidera nuovamente la rego lazione della temperatura ambiente ripetere i passi sopra indicati Allo scopo posizionare la manopola 9 sulla posi...

Page 14: ...ressifs R clamation Le cas ch ant s adresser un installateur sp cialis Montage et r parations Seul un installateur sp cialis est habilit effectuer le montage et les r parations afin de pr server les d...

Page 15: ...s maintenue active via une sonde thermique du r cepteur FR Instructions de montage Le raccordement de l appareil ne doit tre ex cut que par un lectricien sp cialis Un lectricien sp cialis est une pers...

Page 16: ...de courant ne peuvent tre mon t es qu en dehors des zones de protection Remarque le montage des produits dans la zone de protection 1 n est pas autoris par le fabricant Ne monter les produits suivants...

Page 17: ...mbiante est souhait e pour le radiateur par ex parce que la temp rature ambiante est r gul e via un chauffage de sur face proc der selon fig F1 F3 ter le couvercle de bo tier 5 avec pr cau tion Placer...

Page 18: ...18 C1 1 0 2 2 1 0 A B C2...

Page 19: ...19 D4 2x 6 1x 8 7 1x D5 D6 D9 D7 D8 ca 90 mm 9 mm D2 D3 40 mm D1...

Page 20: ...20 N N L L N N PE L L E2 E1 5 0 1 2 3 4 5 9 3 4 1 2 5 F2 F3 F1...