SE-Power FS STO-manual vers. 1.6 en.12.08.2015
55
9.1.4
Electrical data
Control ports STO-A, 0V-A / STO-B, 0V-B [X40]
Nominal voltage
[V]
24 (related to 0V-A/B)
Voltage range
[V]
19,2 … 28,8
Permissible residual ripple
[%]
2 (related to nominal voltage 24 V)
Overvoltage discharge
[V]
31 (disconnect in case of error)
Nominal current
[mA] 20 (typical; maximum 30)
Starting current
[mA] 450 (typical, duration approx. 2ms;
max. 600 at 28.8 V)
Input voltage threshold
Switching on
[V]
approx. 18
Switching off
[V]
approx. 12,5
Switching time from
high to low (STO-A/B_OFF)
[ms]
10 (typical; maximum 20 at 28,8 V)
Switching time from
low to high (STO-A/B_ON)
[ms]
1 (typical; maximum 5)
Maximum positive test
impulse length at logic 0
[µs]
300 (related to nominal voltage 24 V and intervals
2 s between impulses)
Table 21:
Technical data: Electrical for ports STO-A and STO-B
Switch-off time to power output stage inactive and maximum tolerance time for test pulse
Input voltage (STO-A/B)
[V]
19
20
21
22
23
24
25
26
27
28
Typical switch-off time
(STO-A/B_OFF)
[ms] 4,0 4,5 5,0 6,0 6,5 7,0 7,5 8,0 8,5 9,5
Maximum tolerance time for
test pulse at 24 V signal
[ms]
2,0
2,0 2,0 2,5 3,0 3,5 4,5 5,0 5,5 6,0
Table 22:
Typical switch-off time and minimum tolerance time for test pulse (OSSD
signals)