46
SE-Power FS STO-manual vers. 1.6 en.12.08.2015
7
Operation
7.1
Obligations of the operator
The operational capability of the safety equipment must be checked at adequate intervals. It
is the responsibility of the operator to choose the type of check and time intervals in the
specified time period. The check must be made in a way that proves proper functioning of the
safety equipment in interaction with all components.
7.2
Maintenance and care
The safety module does not require any maintenance.
7.3
Protective functions
7.3.1
Voltage monitoring
The input voltages at STO-A and STO-B are monitored. If the input voltage at STO-A or
STO-B is too high or too low, the driver supply for the power semiconductors of the servo
drive are safely switched off. The power output stage (PWM) is thus switched off.
7.3.2
Protection against overvoltage and reverse polarity
The control inputs STO-A and STO-B are protected against overvoltage and reverse polarity
of the control voltage
Section 9.1.4, Table 21
The 24 V DC supply voltage for the servo drive routed to [X40] is short-circuit resistant.