3a 

 

3.3.3  Rear panel 

 
The figures on this page show a VH Series 3000 VA. 
The differences with the rear panel - configuration 
of other models is 

clearly indicated

 in the text 

below. 
 

Input socket 

 

AC mains supply to the UPS 

 

700-2000 VA:

 smaller socket than shown here 

 

Input breaker 

 

Protects the UPS from damage caused by high 
input currents 

 

700-2000 VA:

 breaker has lower rating than 

shown here 

 

Appliance outlets - max. rating 10A 

 

To connect the loads to the UPS. 

 

700 VA: 2 outlets 

 

1000-1500 VA: 4 outlets 

 

2000-3000 VA: 6 outlets 

 
3a  Appliance outlet - max. rating 16A 
 

(

VH Series 3000 VA only)

 

 

To connect a heavy load to the UPS. An output 
cord to connect a load to this outlet is not 
shipped with the unit. 

 

DC connector 

(

not on VH Series 700 VA

)

 

 

To connect a battery extension pack for 
extended battery runtime 

 

Fan(s) 

 

Electronically controlled cooling fan(s). Make 
sure ventilation air can move freely around 
and through the UPS. 

 

USB port 

 

See 5.1 for more information 

 

RJ 11 port 

 

See 5.2 for more information 

 
 
 
 
 

fig. 3.3.3.a:  rear panel - tower (3000 VA 
model) 

3a 

Summary of Contents for 1000 VA VH Series

Page 1: ...User manual VH Series Uninterruptible Power Supply 700 1000 1500 2000 3000 VA...

Page 2: ...ower of the VH Series UPS the rear panel of the UPS shows the model chapter 9 the ratings 3 2 Installation rules The UPS is intended to be used in normal domestic and office situations Protect the UPS...

Page 3: ...ect the DC connector of the internal batteries 5 Assemble the front panel insert the two metal clamps at the rear of the panel into the holes at the right side of the UPS then click the front panel in...

Page 4: ...max rating 10A To connect the loads to the UPS 700 VA 2 outlets 1000 1500 VA 4 outlets 2000 3000 VA 6 outlets 3a Appliance outlet max rating 16A VH Series 3000 VA only To connect a heavy load to the...

Page 5: ...not exceed the VA output rating of the UPS This way you ensure that the UPS is able to supply the required output and prevent that an overload situation will happen 4 Using the output cords provided...

Page 6: ...power fails and the internal batteries supply the required power until either they are depleted or mains power returns 6 LED alarm blinks in case of an alarm 7 LED bar runtime capacity the remaining a...

Page 7: ...this function is activated the UPS will switch off during a mains failure when the load is less than 5 of the maximum load In this way unnecessary discharging of the batteries is avoided The unit will...

Page 8: ...bypass 4 4 3 0 4 0 4 hi o On battery 4 4 4 0 4 0 4 lo Battery low 4 4 5 25 0 4 hi Bypass out of limits 4 4 6 0 4 0 4 lo Overload 4 4 7 0 4 4 hi Replace battery 4 4 8 0 4 0 4 lo General alarm 4 4 9 0 4...

Page 9: ...panel required or if a UPS shutdown command is given by the computer Restart depends on the setting of the auto restart function if set on the UPS will automatically restart when the mains returns if...

Page 10: ...ower failure Allow the UPS to recharge the batteries See also 4 6 4 4 9 General alarm General alarm comprises a group of alarms the buzzer behaviour indicates which alarm is active 1 2 secs General fa...

Page 11: ...the setting of the selected function by pressing switch O The LEDs on the LEDbar runtime capacity shows the setting 4 Store the new settings and leave the setup mode press keypad 1 and keep it presse...

Page 12: ...tery test A deep battery test to be initiated through the UPS software via the USB communication port checks the actual battery capacity in order to ensure accurate runtime prediction During a deep ba...

Page 13: ...al alarm 1 3 Battery low 4 On bypass 5 Remote UPS shutdown RxD 6 GND 1 Active if the output voltage of the UPS is no longer guaranteed due to other circumstances than already indicated by pin 1 3 4 Th...

Page 14: ...the same for all VH Series models NOTE During battery replacement the UPS will not be able to support the load if a mains failure occurs It is recommended to switch off the load before disconnecting...

Page 15: ...lso 4 3 3 Line cord not connected Read 3 3 6 Connect line cord Dead wall socket outlet or mains voltage out of limits Contact qualified electrician Tripped Thermal Circuit Breaker See above UPS switch...

Reviews: