24
d4
Frequency limitation code
0,1,2,4,8,16
Real testing value
d5
Piping temp.
-30
℃~
70
℃
Real testing value
d6
Gas exhaust temperature
0
℃~
C5
℃
(125
℃
)
Real testing value
d7
Step of EEV
0
~
99
N*5
d8
Compressor running frequency
0
~
99Hz
Real testing value
d9
Compressor current
0
~
30A
Real testing value
d10
Current fan speed
0-1200
(
rpm
)
Real testing value
d11
Error code for last time
All error code
Press
first, then press
to check the “ User parameter from P0 to P7
If needed, press
second, then press
or
to adjust the current parameter.
(for example: Press
first, then press
to enter parameter P7 checking, and press
second, then
press
or
to adjust the parameter P7 Inlet water temp. Correction from -9 to 9.)
Code
Name
Scope
Default
Remark
P0
Manual defrost
0-1
0
1 Manual defrosting mode, 0 Normal mode
P1
Working mode
0-1
1
1 Heating mode
,
0 cooling mode
P2
Timer on/off
0-1
0
1 Timer on/off is under function
,
0 Timer on/off is out of
function (The setting of P4 and P5 won’t work)
P3
Water pump
0-1
0
1 Always running
,
0 Depends on the running of compressor
P4
Current time
HH:MM
00
:
00
0-23:0-59
P5
Timer on
HH:MM
00
:
00
0-23:0-59
P6
Timer off
HH:MM
00
:
00
0-23:0-59
P7
Inlet water temp.
correction
-9
~
9
0
Default setting: 0
NOTE: Under defrosting mode, P0=1.
After defrosting finished, it will be automatic enter Normal mode, P0=0.
6.2.4 System reset function
Press
and
in 10s, the system will reset and display “0000” on the controller.
6.2.5
Symbol of heating, the light will be on when it is in operation.
When defrosting, the light will flash.
6.2.6
Symbol of cooling, the light will be on when it is in operation.
Note: When parameter P1 is on checking/adjusting,
and
will be flashing at the same time.
Summary of Contents for Hydro-Pro Inverter 07
Page 7: ...10 2 Dimension mm Model Inverter 7 Model Inverter 11 14 16...
Page 8: ...11 Model Inverter 19 Model Inverter 24 24T 29 29T...
Page 15: ...18 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 11 14 16 19...
Page 16: ...19 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 24...
Page 17: ...20 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 29...
Page 30: ...33 8 Exploded Diagram and Maintenance 8 1 Exploded Diagram Model Inverter 7...
Page 31: ...34...
Page 33: ...36 Model Inverter 24...
Page 34: ...37...