28
EE 15
Temperature of IPM
module is too high
1. Output exception of IPM module
thermal circuit
2. Motor is abnormal or damaged
3. Fan blade is broken
1. Change a driver board
2. Check if the fan motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
EE 16
PFC module
protection
1. Output exception of PFC module
2. Motor is abnormal or damaged
3. Fan blade is broken
4. Input voltage leap, input power is
abnormal
1. Change a driver board
2. Check if the motor speed is too low
or fan motor damaged, change
another one
3. Change another fan blade
4. Check the input voltage
EE 17
DC fan motor failure
1. DC motor is damaged
2. Main board is damaged
3. The fan blade is stuck
1. Detect DC motor, replace with a
new one
2. Change a new main board
3. Find out the barrier and work it out
EE 18
PFC module
thermal circuit is
abnormal
The driver board is damaged
1. Change a new driver board
2. Check if the fan motor speed is too
low or fan motor damaged, change
another one
EE 19
PFC module high
temperature
protection
1. PFC module thermal circuit
output abnormal
2. Motor is abnormal or damaged
3. Fan blade is broken
4. The screw in the driver board is
not tight
1. Change a new driver board
2. Check if the motor speed is too low
or fan motor damaged, change
another one
3. Change another fan blade
4. Check if the screw is loose
EE 20
The input power
failure
Power supply voltage fluctuates too
much
Check whether the voltage is stable
EE 21
Software control
exception
1. Compressor run out of step
2. Wrong program
3. Impurity
inside
compressor
causes the unstable rotate speed
1. Check the main board or change a
new one
2. Enter correct program
EE 22
Current detection
circuit failure
1. Voltage signal abnormal
2. Driver board is damaged
1. Check the main board or change a
new one
2. Change a new driver board
EE 23
Compressor startup
failed
1. Main board is damaged
2. Compressor wiring error or poor
contact or unconnected
3. Liquid accumulation inside
4. Wrong phase connection for
compressor
1. Check the main board or change a
new one
2. Check the compressor wiring
according to the circuit diagram
Check the compressor or change a
new one
EE 24
Ambient
Temperature device
failure on Driver
board
Ambient Temperature device failure
Change driver board or main board
EE 25
Compressor phase
failure
Compressors U, V, W are connected
to one phase or two phases
Check the actual wiring according to
the circuit diagram
Summary of Contents for Hydro-Pro Inverter 07
Page 7: ...10 2 Dimension mm Model Inverter 7 Model Inverter 11 14 16...
Page 8: ...11 Model Inverter 19 Model Inverter 24 24T 29 29T...
Page 15: ...18 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 11 14 16 19...
Page 16: ...19 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 24...
Page 17: ...20 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 29...
Page 30: ...33 8 Exploded Diagram and Maintenance 8 1 Exploded Diagram Model Inverter 7...
Page 31: ...34...
Page 33: ...36 Model Inverter 24...
Page 34: ...37...