background image

40

10. Warranty and returns

10.1 Warranty

LIMITED WARRANTY

Thank you for purchasing a heat pump from us.

This warranty covers manufacturing and material defects in all components for a period of two years after the

date of purchase.

This warranty is limited to the original purchaser in the retail sector. It is not transferable, and it is not

applicable to products that have been removed from their original installation location. The liability of the

manufacturer is limited to the repair or replacement of defective components and does not include the cost of

labour for removing and replacing the defective component(s), the cost of transporting component(s) from or

to the factory, or costs associated with other materials necessary for carrying out repairs. This warranty does

not cover any defects attributable to the following causes:

1.

Installation, operation or maintenance of the product other than in accordance with the guidelines

and/or instructions in the Installation and Operation Manual supplied with the product.

2.

Faulty or deficient work performed on the product by an installer.

3.

Failure to maintain the correct chemical balance in the swimming pool

[pH between 7.0 and 7.8; total

alkalinity (TA) between 80 and 150 ppm; free chlorine concentration between 0.5 and 1.2 mg/l; total

dissolved solids (TDS) less than 1,200 ppm; maximum salt concentration 8 g/l]

.

4.

Improper use, modification, accident, fire, flood, lighting strike, rodents, insects, negligence, neglect,

or force majeure.

5.

Deposits, freezing, or other conditions that impair proper water flow through the product.

6.

Operating the product with a flow rate outside the published minimum and maximum specifications.

7.

Use of components or accessories not designed or made for this product.

8.

Chemical contamination of the air used by the product or improper use of decontaminating chemicals,

such as the addition of decontaminating chemicals through the skimmer or in the pipes or lines located

upstream of the heat pump and the cleaning hose.

9.

Overheating, improper electrical connections, improper power supply, secondary damage attributable

to defective O-rings, diatomaceous filters or filter cartridges, or damage caused by putting the pump into

operation in the absence of sufficient water.

LIMITATIONS ON LIABILITY

This is the sole warranty provided by the manufacturer. Nobody is authorised to grant other warranties in our

name.

THIS WARRANTY REPLACES ALL OTHER EXPLICITLY GRANTED OR IMPLICIT WARRANTIES, INCLUDING BUT

NOT LIMITED TO ANY FORM OF IMPLICIT WARRANTY OF SUITABILITY FOR A PARTICULAR PURPOSE OR

FITNESS FOR SALE. WE EXPLICITLY DISAVOW ANY LIABILITY FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL

LOSS OR DAMAGE OF A PUNITIVE NATURE RESULTING FROM THE VIOLATION OF AN EXPLICITLY GRANTED OR

IMPLICIT WARRANTY.

This warranty gives you specific legal rights, which may vary depending on the country.

WARRANTY CLAIMS

To ensure prompt handling of your warranty claim, please contact your dealer and provide the following

information to the dealer: proof of purchase, model number, serial number and date of installation. The

installer will contact the factory to obtain instructions regarding the procedure for making warranty claims and

to find out the location of the closest service centre.

All returned components must be marked with a

RMA number

so that it can be determined whether they are

covered by the warranty.

Summary of Contents for Hydro-Pro Inverter 07

Page 1: ...nverter 16 horizontal R32 7024519 Hydro Pro Heat pump ABS 230V Inverter type Inverter 19 horizontal R32 7024520 Hydro Pro Heat pump ABS 230V Inverter type Inverter 24 horizontal R32 7024521 Hydro Pro...

Page 2: ...Automated Environmental Systems Ltd 1 Wimbledon Avenue Brandon IP27 0NZ 01842 819130 sales automatedenvironmentalsystems co uk Buy online www automatedenvironmentalsystems co uk...

Page 3: ...e in emission prevention and recovery of fluorinated greenhouse gases and handling safety the relevant type and size of equipment Record keeping 1 Operators of equipment which is required to be checke...

Page 4: ...bility for the damage caused with the people objects and of the errors due to the installation that disobey the manual guideline Any use that is without conformity at the origin of its manufacturing w...

Page 5: ...7 2 4 6 Compressor type Inverter Compressor Voltage V 220 240V 50Hz 1PH Rated current A 5 5 7 9 10 0 11 8 Minimum fuse A 9 12 15 16 Advised pool volume with pool cover m 10 25 15 60 18 66 25 85 Advis...

Page 6: ...e V 220 240V 50Hz or 60Hz 1PH 380V 50Hz or 60Hz 3PH 220 240V 50Hz or 60Hz 1PH 380V 50Hz or 60Hz 3PH Rated current A 14 0 17 7 6 9 21 0 8 2 Minimum fuse A 21 27 10 34 13 Advised pool volume with pool c...

Page 7: ...10 2 Dimension mm Model Inverter 7 Model Inverter 11 14 16...

Page 8: ...11 Model Inverter 19 Model Inverter 24 24T 29 29T...

Page 9: ...city 3 Swimming pool filters The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other objects are maintained see drawing below Please consult you...

Page 10: ...ity pH is used it is essential to protect the heat pump against excessively high chemical concentrations which may corrode the heat exchanger For this reason equipment of this sort must always be fitt...

Page 11: ...nd terminal block marked WATER PUMP is located next to the first one The filter pump switch 24V can be connected to the second terminal block here This allows the filter pump operation to be controlle...

Page 12: ...ime delay The heat pump has a built in 3 minute start up delay to protect the circuitry and avoid excessive contact wear The unit will restart automatically after this time delay expires Even a brief...

Page 13: ...essories Installation Anti vibration bases 1 Take out 4 Anti vibration bases 2 Put them one by one on the bottom of machine like the picture Draining jet 1 Install the draining jet under the bottom pa...

Page 14: ...the two joints like the picture shows 3 Screw them onto the water Inlet outlet junction Cable wiring 1 Open the terminal cover 2 Fix the power supply wire on joints Water pump wiring 1 Open the termi...

Page 15: ...18 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 11 14 16 19...

Page 16: ...19 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 24...

Page 17: ...20 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 29...

Page 18: ...y isolated from the rest of the unit Grounding the unit is still required to protect you against short circuits inside the unit Bonding is also required Disconnect A disconnect means circuit breaker f...

Page 19: ...photo5 6 Display Controller Operation 6 1 The buttons of LED wire controller 6 2 The keys and their operations NOTE Every time when the heat pump connects to the power the LED display shows a code for...

Page 20: ...r temperature Tset Current water in temperature Tset 2 Current working mode After 3 minutes or above it will switch to Tset eg 28 Tset 2 eg 30 Heating mode Cooling mode Tset eg 28 Tset 2 eg 26 Cooling...

Page 21: ...st 0 1 0 1 Manual defrosting mode 0 Normal mode P1 Working mode 0 1 1 1 Heating mode 0 cooling mode P2 Timer on off 0 1 0 1 Timer on off is under function 0 Timer on off is out of function The setting...

Page 22: ...light will be flash the heat pump will operate in Full output only 6 2 10 While you choose the Smart the heat pump will just operate in Small output Medium output and Full output When in Small output...

Page 23: ...ck the wiring for water flow switch 2 Change the water flow switch 3 Check the water pump or the waterway system EE 04 Over heating protection for water temperature T2 in heating mode 1 Low water flow...

Page 24: ...rd EE 11 IPM module protection 1 Data mistake 2 Wrong compressor phase connection 3 Compressor liquid and oil accumulation lead to the current becomes larger 4 Compressor or driver board damaged 1 Pro...

Page 25: ...Fan blade is broken 4 The screw in the driver board is not tight 1 Change a new driver board 2 Check if the motor speed is too low or fan motor damaged change another one 3 Change another fan blade 4...

Page 26: ...1 Re fix the wiring of the sensors 2 Change the sensor PP 04 Gas return sensor failure 1 The sensor failure or short circuit 2 The wiring of sensor is loose 1 Re fix the wiring of the sensors 2 Chang...

Page 27: ...ple below Mode Water out temperature Setting temperature Condition Malfunction Heating mode 36 29 Tout Tset 7 EE04 Overheating protection for water temperature T2 Cooling mode 23 30 Tset Tout 7 PP11 T...

Page 28: ...T1 27 last for 30 minutes Water pump will enter standby mode for 2 hours and will not start except turn off power supply and restart Heat pump will restart 3 minutes after the water pump exit the sta...

Page 29: ...ose the wrong mode 2 Figures show defects 3 Controller defect 1 Adjust the mode to proper running 2 Replace the defect LED wire controller and then check the status after changing the running mode ver...

Page 30: ...33 8 Exploded Diagram and Maintenance 8 1 Exploded Diagram Model Inverter 7...

Page 31: ...34...

Page 32: ...motor 45 Water inlet temp sensor clip 14 Left panel 46 Titanium heat exchanger 15 Fan blade 47 O ring 16 Front panel 48 Blue rubber ring 17 Controller box 49 Water connection 18 Ventilation grid 50 R...

Page 33: ...36 Model Inverter 24...

Page 34: ...37...

Page 35: ...id reservoir to EEV 17 Bracket for panel 55 Pipe Filter to Liquid reservoir 18 Fan motor 56 Pipe EEV to Distribution 19 Fan blade 57 EEV 20 DC motor casing tube 58 Filter 21 Controller box 59 Pipe Tit...

Page 36: ...as a result of the dirty of clogged filter 3 You should discharge the water from bottom of heat exchanger if HP unit will stop running for a long time specially during the winter season 4 In another...

Page 37: ...he product with a flow rate outside the published minimum and maximum specifications 7 Use of components or accessories not designed or made for this product 8 Chemical contamination of the air used b...

Page 38: ...hipping service of your choice 4 If you choose express shipment by a shipping service selected by you you are responsible for paying the shipping costs Return procedure 1 Before requesting an RMA numb...

Page 39: ...MA number we will return all of the products at your expense 10 No return shipments at all will be accepted without an RMA number Absolutely no exceptions to this rule are allowed 11 An RMA number rem...

Reviews: