30
Remarks:
1. In heating mode, if the water out temperature is higher than the set temperature over 7
℃
, LED controller
displays EE04 for water over-heating protection.
2. In cooling mode, if the water out temperature is lower than the set temperature over 7
℃
, LED controller displays
PP11 for water over-cooling protection.
For example below:
Mode
Water out
temperature
Setting
temperature
Condition
Malfunction
Heating mode
36
℃
29
℃
Tout - Tset
≧
7
℃
EE04
Overheating protection for water
temperature (T2)
Cooling mode
23
℃
30
℃
Tset - Tout
≧
7
℃
PP11
Too low protection for water
temperature (T2)
T
SET Temp.
+7
℃
T
SET Temp.
+5
℃
Frequency Decrease
EE04 Water Overheating Protection
PP11 Water Overcooling Protection
护
Compressor Stop and EE04 displays
T
water out
(℃)
Normal Operation
T
water out
(℃)
T
SET Temp.
-7
℃
T
SET Temp.
-5
℃
Normal Operation
Frequency Decrease
Compressor Stop and PP11 displays