Press
to stop the heat pump unit and show “OFF”
Notice : During the parameter checking and setting, press the
to quick-exit and save the current setting .
Press
again to turn on/off the machine.
6.2.2
button
Automatic mode:
Press
for 5 seconds to switch to automatic mode.(default:Smart mode)
Press
for 5 seconds again to exit automatic mode and switch to heating mode(default:Smart mode)
Note:Under Automatic mode, it is useless to set parameter P1 .
Operation logic of Auto Mode:
Set water temperature
(Tset)
Current water in
temperature
(Tset +2
℃
)
Current working
mode
After 3 minutes or
above, it will switch to
Tset (eg: 28
℃
)
Tset +2
℃
(eg:30
℃
)
Heating mode
Cooling mode
Tset (eg: 28
℃
)
Tset-2
℃
(eg: 26
℃
)
Cooling mode
Heating mode
6.2.3
and
button
Clock/unclock the display:
Hold
and
for 5 seconds to lock/Unlock the display.
Water temperature setting :
Press
or
to set the water temperature directly.
Parameter checking :
Press
first, then press
to check the “ User parameter from d0 to d11
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120
℃
Real testing value
d1
Inlet water temp.
-9
℃~
99
℃
Real testing value
d2
Outlet water temp.
-9
℃~
99
℃
Real testing value
d3
Ambient temp.
-30
℃~
70
℃
Real testing value
Summary of Contents for Hydro-Pro Inverter 07
Page 7: ...10 2 Dimension mm Model Inverter 7 Model Inverter 11 14 16...
Page 8: ...11 Model Inverter 19 Model Inverter 24 24T 29 29T...
Page 15: ...18 5 Electrical Wiring 5 1 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 7 11 14 16 19...
Page 16: ...19 5 2 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 24...
Page 17: ...20 5 3 SWIMMING POOL HEAT PUMP WIRING DIADRAM Inverter 29...
Page 30: ...33 8 Exploded Diagram and Maintenance 8 1 Exploded Diagram Model Inverter 7...
Page 31: ...34...
Page 33: ...36 Model Inverter 24...
Page 34: ...37...