28
Troubleshooting
Analyzer Control – Error Codes and Check Salt Light
Problem
Possible Cause
Solution
ERR 1 is displayed.
Program settings have been corrupted.
Press any key and reprogram Level I settings.
ERR 2 is displayed.
The control is not a “North American”
60 Hz model.
Install 60 Hz Analyzer control.
ERR 3 is displayed.
Control does not know the position of the
camshaft. Camshaft should be rotating
to find Home position.
Wait for two minutes for the control to return to
Home position. The hourglass should be flashing
on the display indicating the motor is running.
Camshaft is not turning
during ERR 3 display.
Check that motor is connected. Verify that motor wire
harness is connected to motor and control module.
Verify that optical sensor is connected and in place.
Verify that motor gear has engaged cam gear.
If everything is connected, try replacing in this order:
1. Wire harness, motor, optical sensor assembly
2. Control
Camshaft is turning more than five
minutes to find Home position.
Verify that optical sensor is in place and
connected to wire.
Verify that camshaft is connected appropriately.
Verify that no dirt or rubbish is clogging any of
the cam slots.
If motor continues to rotate indefinitely, replace
the following components in this order:
1. Wire harness, motor, optical sensor assembly
2. Control
Err 6 is displayed.
Defective or disconnected probe.
Replace or reconnect probe.
Check Salt Light is displayed on
valve control or brine tank empty
icon is displayed on remote
monitor - Press the regen button
to turn off the check salt light.
No regenerant draw or insufficient
regenerant detected during regeneration.
Ensure salt/regenerant is available.
Check for regenerant draw.
Inspect regenerant line for leaks.
Remote monitor icons
partially displayed.
Remote monitor not receiving a signal.
Reduce obstacles between monitor and controller.
Move monitor closer to controller.
Remote monitor icons not
displayed.
Weak/dead battery.
Replace battery.